Do not install the air conditioner at any place where 
there is a danger of flammable gas leakage.

In the event of a gas leakage, build-up of gas near the air 
conditioner may result in fire hazards.

Do not put flammable containers, such as spray 
cans, within 1 m from the blow-off mouth.

The containers may explode because the warm air out-
put of the indoor or outdoor unit will affect them.

Arrange the drain to ensure complete drainage.

If proper drainage from the outdoor drain pipe does not 
occur during air conditioner operation, there could be a 
blockage due to dirt and debris build-up in the pipe. This 
may result in a water leakage from the indoor unit. Under 
these circumstances, stop air conditioner operation and 
consult your dealer for assistance.

The appliance is not intended for use by unattended 
young children or infirm persons.

Impairment of bodily functions and harm to health may result. 

Children should be supervised to ensure that they 
do not play with the unit or its remote controller.

Accidental operation by a child may result in impairment 
of bodily functions and harm health.

Do not let children play on or around the outdoor 
unit.

If they touch the unit carelessly, injury may be caused. 

To avoid injury, do not touch the air inlet or alumin-
ium fins of the unit. 

Do not place objects in direct proximity of the out-
door unit and do not let leaves and other debris 
accumulate around the unit. 

Leaves are a hotbed for small animals which can enter 
the unit. Once in the unit, such animals can cause mal-
functions, smoke or fire when making contact with elec-
trical parts.

Turn off the power when the unit is not to be used for 
long periods of time.

Otherwise, the unit may get hot or catch on fire due to 
dust accumulation.

Never touch the internal parts of the controller. 

Do not remove the front panel. Touching certain internal 
parts will cause electric shocks and damage to the unit. 
Please consult your dealer about checking and adjust-
ment of internal parts. 

Do not leave the remote controller wherever there is 
a risk of wetting.

If water gets into the remote controller there is a risk of 
electrical leakage and damage to electronic compo-
nents.

Watch your steps at the time of air filter cleaning or 
inspection.

High-place work is required, to which utmost attention 
must be paid.
If the scaffold is unstable, you may fall or topple down, 
thus causing injury.

This appliance is not intended for use by persons 
(including children) with reduced physical, sensory 
or mental capabilities, or lack of experience and 
knowledge, unless they have been given supervision 
or instruction concerning use of the appliance by a 
person responsible for their safety.

Children should be supervised to ensure that they 
do not play with the appliance.

OPERATION RANGE

If the temperature or the humidity is beyond the following con-
ditions, safety devices may work and the air conditioner may 
not operate, or sometimes, water may drop from the indoor unit.

COOLING

HEATING
For FCQ50 · 60 · 71 · 100 · 125 · 140KVEA

For FCQN71 · 100 · 125 · 140KVEA

D B: Dry bulb temperature (°C)
WB: Wet bulb temperature (°C)

The setting temperature range of the remote controller is 
16°C to 32°C.

„

Tips for saving energy

• Be careful not to cool (heat) the room too much.

Keeping the temperature setting at a moderate level 
helps save energy.

• Cover windows with a blind or a curtain.

Blocking sunlight and air from outdoors increases the 

cooling (heating) effect.

INSTALLATION SITE

Regarding places for installation

• Is the air conditioner installed at a well-ventilated 

place where there are no obstacles around?

• Do not use the air conditioner in the following places.

a. Filled with much mineral oil such as cutting oil

b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring resort

OUTDOOR 

UNIT

INDOOR

OUTDOOR 
TEMPERA-

TURE

TEMPERA-

TURE

HUMIDITY

RZQ 50 

60
71
100
125
140

RQ

71
100
125
140

D
B

21 to 32

80% or below

D
B

–5 to 46

W

B

14 to 25

OUTDOOR 

UNIT

INDOOR 

TEMPERATURE

OUTDOOR 

TEMPERATURE

RZQ 50 

60
71
100
125
140

D

B

15 to 27

D
B

–15 to 21

W

B

–15 to 16

OUTDOOR 

UNIT

INDOOR 

TEMPERATURE

OUTDOOR 

TEMPERATURE

RQ

71
100
125
140

D

B

15 to 27

D
B

–10 to 21

W

B

–10 to 16

Recommended temperature setting

For cooling

26 to 28 °C

For heating

20 to 24 °C

01_EN_3P177429-9S.fm  Page 6  Saturday, October 16, 2010  2:24 PM

Содержание FCQ50KVEA

Страница 1: ...for purchasing this Daikin air conditioner Carefully read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs This m...

Страница 2: ...EST C hr hr TEST NOT AVAILABLE L H 2 9 10 3 1 4 5 6 7 13 14 15 16 17 18 19 20 21 11 8 12 a c d e l m g f h i k j e b d n RZQ100 125 140 RZQ 50 60 71 C hr H 3 figure 1 00_CV_3P177429 9S fm Page 2 Satur...

Страница 3: ...N They both contain important information regarding safety Be sure to observe all precautions without fail WARNING Failure to follow these instructions properly may result in personal injury or loss o...

Страница 4: ...ve oily smoke such as cooking rooms or in places with flammable gas corrosive gas or metal dust Using the product in such places may cause fire or prod uct failures Do not use flammable materials e g...

Страница 5: ...ing If water gets into the remote controller there is a risk of electrical leakage and damage to electronic compo nents Watch your steps at the time of air filter cleaning or inspection High place wor...

Страница 6: ...button Press the button and the system will start Press the button again and the system will stop 2 OPERATION lamp RED The lamp lights up during operation 3 DISPLAY UNDER CENTRALIZED CONTROL When thi...

Страница 7: ...on running for about 1 minute after the heating operation stops To start the next operation smoothly ATTENTION Do not turn OFF power immediately after the unit stops Then wait no less than 5 minutes W...

Страница 8: ...mfortable environment Avoid excessive heating or cooling Prevent direct sunlight from entering a room during cooling operation by using curtains or blinds Ventilate the room regularly Using the unit f...

Страница 9: ...shade NOTE Do not wash the air conditioner with hot water of more than 50 C as doing so may result in discoloration and or defor mation Do not expose it to fire as doing so may result in burning 4 Fi...

Страница 10: ...h is connected Might there be a broken wire somewhere Contact your dealer if there are any problems Clean the air filter and outside panels After cleaning the air filter make sure to attach it Turn on...

Страница 11: ...ntinuous low Shah sound is heard when the system is in COOLING OPERATION or at a stop The noise is heard when the drain pump is in operation A Pishi pishi squeaking sound is heard when the system is i...

Страница 12: ...it well ventilated Check if the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE 3 The system operates but it does not sufficiently cool or heat If th...

Страница 13: ...3P177429 9S EM10A035 1011 HT 00_CV_3P177429 9S fm Page 3 Saturday October 16 2010 2 12 PM...

Отзывы: