16
English
Precautions to be taken for power supply wiring
Use a round crimp-style terminal for connection to the power supply terminal block. (Refer to Fig. 23)
In case it cannot be used due to unavoidable reasons, be sure to observe the following instructions.
•
Do not connect wires of different diameter to the same power supply terminal. (Looseness in the connec-
tion may cause overheating.)
(Refer to Fig. 24)
•
In wiring, make certain that prescribed wires are used. Also, fix the wires so that external force may not be
applied to the terminals.
Tightening torque for the terminal screws
•
Use an appropriate screwdriver to tighten the terminal screws. If the blade of screwdriver is too small, the
head of the screw might be damaged, and the screw will not be properly tightened.
•
If the terminal screws are tightened too hard, screws might be damaged.
Refer to the Table 4 for the tightening torque of the terminal screws.
Table 4
•
If the strand wire is used, do not solder it.
Tightening torque (N·m)
Terminal block for remote controller wiring
0.79 to 0.97
Terminal block for wiring between the units
1.18 to 1.44
Earth terminal
1.18 to 1.44
Electric wire
Attach insulation sleeve
Round crimp-style terminal
Fig. 23
Good
Wrong
Wrong
Connect wires of the
same gauge to both
side. (GOOD)
Do not connect wires
of the same gauge to
one side. (WRONG)
Do not connect wires
of different gauges.
(WRONG)
Fig. 24
4PEN468968-1C.book Page 16 Friday, March 24, 2017 1:30 PM