![Daikin ERGA06EAV3H Скачать руководство пользователя страница 123](http://html1.mh-extra.com/html/daikin/erga06eav3h/erga06eav3h_installers-reference-manual_4277598123.webp)
9
|
Electrical installation
Installer reference guide
123
ERGA04~V3A+V37 + EHSH/X(B)04+08P30+50EF
Daikin Altherma 3 R ECH₂O
4P678716-1 – 2022.01
—
A
2x
B
X1M
1 2 3 4 5 6
A
B
2x
b
a
a
1 2 3
b
L
N
F2B
1
3
2
4
I
I
Q DI
2
6
5
230
, 6.3 A
V AC
1N~, 50 Hz,
a
Interconnection cable
b
Power supply indoor unit
In case of preferential kWh rate power supply
Interconnection cable
Wires: (3+GND)×1.5 mm²
Power supply indoor
unit
Wires: 1N+GND
Maximum running current: 6.3 A
Preferential kWh rate
power supply contact
Wires: 2×(0.75~1.25 mm²)
Maximum length: 50 m.
Preferential kWh rate power supply contact:
16 V DC detection (voltage supplied by PCB). The
voltage-free contact shall ensure the minimum
applicable load of 15 V DC, 10 mA.