EKHBRD011~Y1
Indoor unit for air to water heat pump system
4PW54465-1A
Installation manual
34
U
NIT
SPECIFICATIONS
Technical specifications
Electrical specifications
011
014
016
V1
Y1
V1
Y1
V1
Y1
Nominal capacity
(kW)
11.2
11.2
14
14
16
16
Casing material
Pre-coated sheet metal
Pre-coated sheet metal
Pre-coated sheet metal
Dimensions H x W x D
(mm)
705 x 600 x 695
705 x 600 x 695
705 x 600 x 695
Weight
• with packaging
(kg)
153
156
153
156
153
156
• without packaging
(kg)
144
147
144
147
144
147
Connections
• water inlet/outlet
G 1"1/4 (female)
G 1"1/4 (female)
G 1"1/4 (female)
G 1"1/4 (female)
G 1"1/4 (female)
G 1"1/4 (female)
• water drain
drain valve
drain valve
drain valve
drain valve
drain valve
drain valve
• water shut-off valve material
Brass-CW 617N
Brass-CW 617N
Brass-CW 617N
Brass-CW 617N
Brass-CW 617N
Brass-CW 617N
• refrigerant liquid side
(mm)
Ø9.5 (3/8 inch)
Ø9.5 (3/8 inch)
Ø9.5 (3/8 inch)
Ø9.5 (3/8 inch)
Ø9.5 (3/8 inch)
Ø9.5 (3/8 inch)
• refrigerant gas side
(mm)
Ø15.9 (5/8 inch)
Ø15.9 (5/8 inch)
Ø15.9 (5/8 inch)
Ø15.9 (5/8 inch)
Ø15.9 (5/8 inch)
Ø15.9 (5/8 inch)
Expansion vessel
• volume
(l)
12
12
12
12
12
12
• maximum working pressure (MWP)
(bar)
4
4
4
4
4
4
Pump
• type
DC motor
DC motor
DC motor
DC motor
DC motor
DC motor
• no. of speed
inverter controlled inverter controlled inverter controlled inverter controlled inverter controlled inverter controlled
Sound pressure level
(a)
(dBA)
42 dBA
42 dBA
44 dBA
42 dBA
42 dBA
42 dBA
Internal water volume
(l)
20
20
20
20
20
20
Pressure relief valve water circuit
(bar)
3
3
3
3
3
3
Operation range - water side
(°C)
25~80
25~80
25~80
25~80
25~80
25~80
Operation range - outdoor
• space heating
(°C)
–20~+20
–20~+20
–20~+20
–20~+20
–20~+20
–20~+20
• domestic hot water
(°C)
–20~+35
–20~+35
–20~+35
–20~+35
–20~+35
–20~+35
(a) At 1 m in front of the unit (free field condition) at nominal values: ambient temperaure of 7°C/6°C and heating set point 65°C/75°C.
011
014
016
V1
Y1
V1
Y1
V1
Y1
Phase
1N~
3N~
1N~
3N~
1N~
3N~
Frequency
(Hz)
50
50
50
50
50
50
Voltage range
• minimum
(V)
220
380
220
380
220
380
• maximum
(V)
240
415
240
415
240
415
Voltage tolerance
–10%/+6%
–10%/+6%
–10%/+6%
–10%/+6%
–10%/+6%
–10%/+6%
Maximum running current
(A)
21.7
12.5
21.7
12.5
21.7
12.5
Recommended field fuse
(A)
32
20
32
20
32
20
Содержание EKHBRD011AAV1
Страница 41: ...V1 Y1 NOTES 5 5 ...
Страница 42: ...4PW54465 1A Copyright Daikin ...