EKHBH/X016BB

Indoor unit and options for air to water heat pump system

4PW62573-1 – 10.2010

Operation manual

8

Displaying actual temperatures

1

Push the 

ba

 button for 5 seconds.

The 

b

  icon and the entering water temperature are displayed.

The icons 

l

 and 

=

 are flashing.

2

Use the 

pi

 and 

pj

 buttons to display:

If no button is pressed for 5 seconds, the controller leaves the
display mode.

Schedule timer operation

In schedule timer operation, the installation is controlled by the
schedule timer. The actions programmed in the schedule timer will be
executed automatically.

The schedule timer always follows the last command until a new
command is given. This means that the user can temporarily overrule
the last executed programmed command by manual operation (Refer
to 

"Manual operation" on page 7

). The schedule timer will regain

control over the installation as soon as the next programmed
command of the schedule timer occurs.

The schedule timer is enabled (

p

 icon displayed) or disabled (

p

 icon

not displayed), by pressing the 

pr

 button.

To set up the SCHEDULE TIMER refer to chapter 

"4.7. Programming

and consulting the schedule timer" on page 9

.

What can the schedule timer do?

The schedule timer allows the programming of:

1.

Space heating (refer to 

"Programming space heating or

domestic water heating" on page 10

)

Switch on the desired mode at a scheduled time, in combination
with a set point (weather dependent or manually set). 
Four actions per weekday can be programmed, totalling
28 actions.

2.

Space cooling (refer to 

"Programming space cooling, quiet

mode, or booster heater mode" on page 11

).

Switch on the desired mode at a scheduled time, in combination
with a set point (weather dependent or manually set). Four
actions can be programmed. These actions are repeated daily.

3.

Quiet mode (refer to 

"Programming space cooling, quiet mode,

or booster heater mode" on page 11

)

Switch the mode on or off at a scheduled time. Four actions can
be programmed per mode. These actions are repeated daily.

4.

Domestic water heating (refer to 

"Programming space heating or

domestic water heating" on page 10

)

[4-03]=0, 1, 2, or 3

Switch the mode on or off at a scheduled time. Four actions per
weekday can be programmed, totalling 28 actions.

[4-03]=4 or 5

Switch the mode on or off at a scheduled time. The switch set to
on means enabeling the programmed storage and reheat
operation.

Flashing icon(s)

Meaning

h

 or 

c

The entering water temperature

h

 or 

c

 and 

é

The outgoing water temperature after plate heat 
exchanger

h

 or 

c

 and 

)

The outgoing water temperature after backup 
heater

ç

The liquid refrigerant temperature

u

The outdoor temperature

w

The domestic hot water temperature

INFORMATION

Only use the 

pr

  button to enable or disable the

schedule timer. The schedule timer overrules the 

y

button. The 

y

  button only overrules the schedule

timer until the next programmed action.

If the auto restart function is disabled, the schedule
timer will not be activated when power returns to the
unit after a power supply failure. Press the 

pr

 button

to enable the schedule timer again.

When power returns after a power supply failure, the
auto restart function reapplies the user interface
settings at the time of the power supply failure.
It is therefore recommended to leave the auto restart
function enabled.

The programmed schedule is time driven. Therefore, it
is essential to set the clock and the day of the week
correctly. Refer to 

"Setting the clock" on page 5

.

Manually adjust the clock for summertime and
wintertime. Refer to 

"Setting the clock" on page 5

.

A power failure exceeding 2 hours will reset the clock
and the day of the week. The schedule timer will
continue operation, but with a disordered clock. Refer
to 

"Setting the clock" on page 5

  to adjust the clock

and the day of the week.

The actions programmed in the schedule timer will not
be lost after a power failure so that reprogramming the
schedule timer is not required.

INFORMATION

When the unit is connected to an external room
thermostat, the schedule timer for space heating and
space cooling is overruled by the external room
thermostat.

INFORMATION

The programmed actions are not stored according to
their timing but according to the time of programming.
This means that the action that was programmed first
gets action number 1, even though it is executed after
other programmed action numbers.

When the schedule timer switches space heating or
space cooling 

x

, the controller will also be

switched off. Note that this has no influence on
domestic water heating.

[4-03]=4 or 5. In case no domestic water heating
actions are programmed, enabling or disabling the
schedule timer will only have influence on the space
heating, cooling and quite mode. In this way it is
possible to separate on one hand the space heating,
cooling and quite mode scheduled action as part of
the schedule timer and on the other hand the storage
and reheat operation of the domestic water heating.
In this way, it is easy to disable the space heating and
cooling by disabling the schedule timer with keeping
the storage and reheat domestic water heating
enabled (refer to 

"Scheduled domestic hot water

storage" on page 

15

  and 

"Scheduled/continuous

domestic hot water reheat" on page 15

).

NOTICE

The setting [4-03] shall not be modified. The installer
selected the proper setting for your application.

Содержание EKHBH016BB3V3

Страница 1: ...BB EKHBX016BB Indoor unit and options for air to water heat pump system EKHBH016BB3V3 EKHBH016BB6V3 EKHBH016BB6WN EKHBH016BB6T1 EKHBH016BB9WN EKHBH016BB9T1 EKHBX016BB3V3 EKHBX016BB6V3 EKHBX016BB6WN EK...

Страница 2: ...this manual are classified according to their severity and probability of occurrence Some types of danger are represented by special symbols 1 2 Meaning of used terms Installation manual Instruction m...

Страница 3: ...ent sizes 200 and 260 litre Solar kit for domestic hot water tank option For information concerning the EKSOLHW solar kit refer to the installation manual of that kit Room thermostat kit option An opt...

Страница 4: ...ipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there mu...

Страница 5: ...ATURE DISPLAY 9 The display shows the current space heating cooling set temperature of the installation 12 SETTING Not used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whe...

Страница 6: ...orage set point of the domestic hot water temperature only for 4 03 4 or 5 The buttons are not used when the domestic hot water tank is not installed 34 QUIET MODE BUTTON s This button enables or disa...

Страница 7: ...int upon user request 2 Reheat Scheduled The unit will heat up the domestic water tank starting from a scheduled time and untill the reheat set point is reached Preferally this is done during the time...

Страница 8: ...ng operation 1 Press v for 5 seconds to activate powerful domestic water heating operation For EKHW only Icons w and m start flashing 1 For EKHTS only Icons w and start flashing 2 Powerful domestic wa...

Страница 9: ...iquid refrigerant temperature u The outdoor temperature w The domestic hot water temperature INFORMATION Only use the pr button to enable or disable the schedule timer The schedule timer overrules the...

Страница 10: ...m at the very end of this manual This form can help you define the required actions for each day Keep in mind that In the space heating and domestic water heating program 4 actions can be programmed p...

Страница 11: ...e programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the ba button to select For space heating x switch heating and the controller off 9 set the...

Страница 12: ...select For space cooling x switch cooling and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation For quiet mode and booster heater...

Страница 13: ...button The actual mode is blinking 2 Use the pi and pj buttons to select the mode you want to program The selected mode is blinking You can leave programming by pressing the pr button 3 Press the but...

Страница 14: ...n 6 Repeat step 2 through 4 to change other field settings as required 7 When finished press the z button to exit FIELD SET MODE Detailed description 0 User permission level If required certain user i...

Страница 15: ..._Ti the target outgoing water temperature when the outdoor temperature equals or rises above the high ambient temperature Hi2_A Note that the Hi2_Ti value should be lower than Lo2_Ti as for warmer out...

Страница 16: ...nt hysteresis Example 1 Scheduled storage 6 03 1 scheduled reheat 6 05 1 disinfection function 2 01 1 activated A Scheduled storage operation activated at 6 04 heat up domestic hot water untill domest...

Страница 17: ...ng automatic storage during night default setting If it seems that the domestic hot water night storage operation is not sufficient for your needs an additional scheduled reheat during daytime can be...

Страница 18: ...it refer to the installation manual of that kit d Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case...

Страница 19: ...n All 01 Status 1 ON 0 1 02 Start time 23 00 0 00 23 00 1 00 hour 03 Set point only in combination with domestic hot water tank without electrical booster heater EKHTS 60 fixed 5 C 03 Set point only i...

Страница 20: ...related setting 9 Heating and cooling set point ranges 00 Heating set point upper limit 55 37 55 1 C 01 Heating set point lower limit 25 15 37 1 C 02 Cooling set point upper limit 22 18 22 1 C 03 Coo...

Страница 21: ...Unit information readout 00 Software version Read only 01 EEPROM version Read only 02 Unit model identification Do not change the default value depending on model 03 Liquid refrigerant temperature Re...

Страница 22: ...nt of oil and other parts must be done by a qualified installer in accordance with the applicable legislation Units must be treated at a specialized treatment facility for re use recycling and recover...

Страница 23: ......

Страница 24: ...4PW62573 1 10 2010 Copyright 2010 Daikin...

Отзывы: