background image

Operation manual

1

EKHBH/X016BB

Indoor unit and options for air to water heat pump system

4PW62573-1 – 10.2010

C

ONTENTS

Page

1.

Definitions.................................................................................. 1

1.1.

Meaning of warnings and symbols................................................. 1

1.2.

Meaning of used terms .................................................................. 1

2.

General safety precautions........................................................ 2

3.

Introduction................................................................................ 2

3.1.

General information........................................................................ 2

3.2.

Scope of this manual ..................................................................... 2

4.

Operating the unit ...................................................................... 3

4.1.

Introduction .................................................................................... 3

4.2.

Operating the digital controller ....................................................... 3
Features and functions................................................................... 3
Basic controller functions ............................................................... 3
Clock function................................................................................. 3
Schedule timer function ................................................................. 3

4.3.

Name and function of buttons and icons........................................ 4

4.4.

Setting up the controller ................................................................. 5
Setting the clock............................................................................. 5
Setting the schedule timer ............................................................. 5

4.5.

Description of the operation modes ............................................... 6
Space heating operation (

h

).......................................................... 6

Space cooling operation (

c

) .......................................................... 6

Domestic water heating operation (

w

) .......................................... 6

Powerful domestic water heating operation ................................... 6
Quiet mode operation (

s

) ............................................................ 7

4.6.

Controller operations...................................................................... 7
Manual operation ........................................................................... 7
Schedule timer operation ............................................................... 8

4.7.

Programming and consulting the schedule timer ........................... 9
Programming................................................................................ 10
Consulting programmed actions .................................................. 12
Tips and tricks .............................................................................. 12

5.

Field settings ........................................................................... 13

5.1.

Procedure .................................................................................... 13
Detailed description ..................................................................... 13
Field settings table ....................................................................... 18

6.

Maintenance ............................................................................ 21

6.1.

Important information regarding the refrigerant used................... 21

6.2.

Maintenance activities.................................................................. 21

6.3.

Standstill ...................................................................................... 21

7.

Troubleshooting ....................................................................... 21

8.

Disposal requirements............................................................. 21

The original instructions are written in English. All other languages
are translations of the original instructions.

This appliance is not intended for use by persons, including children,
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with
the appliance.

1. D

EFINITIONS

1.1.

Meaning of warnings and symbols

Warnings in this manual are classified according to their severity and
probability of occurrence.

Some types of danger are represented by special symbols:

1.2.

Meaning of used terms

Installation manual:

Instruction manual specified for a certain product or application,
explaining how to install, configure and maintain it.

Operation manual:

Instruction manual specified for a certain product or application,
explaining how to operate it.

Maintenance instructions:

Instruction manual specified for a certain product or application,
which explains (if relevant) how to install, configure, operate and/or
maintain the product or application.

Dealer:

Sales distributor for products as per the subject of this manual.

Installer:

Technical skilled person who is qualified to install products as per the
subject of this manual.

User:

Person who is owner of the product and/or operates the product.

Service company:

Qualified company which can perform or coordinate the required
service to the unit.

EKHBH016BB***
EKHBX016BB***

Indoor unit and options for air to water 

heat pump system

Operation manual

CAREFULLY READ THESE INSTRUCTIONS BEFORE
OPERATING THE UNIT. THEY WILL TELL YOU HOW TO
USE THE UNIT PROPERLY. KEEP THIS MANUAL IN A
HANDY PLACE FOR FUTURE REFERENCE.

WARNING

Before operating the unit, be sure the installation has been
carried out correctly by an installer.

If you feel unsure about operation, contact your installer for
advice and information.

DANGER

Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.

WARNING

Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also
be used to alert against unsafe practices.

NOTICE

Indicates situations that may result in equipment or
property-damage accidents only.

INFORMATION

This symbol identifies useful tips or additional information.

Electric current.

Danger of burning and scalding.

Содержание EKHBH016BB3V3

Страница 1: ...BB EKHBX016BB Indoor unit and options for air to water heat pump system EKHBH016BB3V3 EKHBH016BB6V3 EKHBH016BB6WN EKHBH016BB6T1 EKHBH016BB9WN EKHBH016BB9T1 EKHBX016BB3V3 EKHBX016BB6V3 EKHBX016BB6WN EK...

Страница 2: ...this manual are classified according to their severity and probability of occurrence Some types of danger are represented by special symbols 1 2 Meaning of used terms Installation manual Instruction m...

Страница 3: ...ent sizes 200 and 260 litre Solar kit for domestic hot water tank option For information concerning the EKSOLHW solar kit refer to the installation manual of that kit Room thermostat kit option An opt...

Страница 4: ...ipate this gas safely it is recommended that a hot tap be turned on for several minutes at a sink basin or bath but not at a dishwasher clothes washer or other appliance During this procedure there mu...

Страница 5: ...ATURE DISPLAY 9 The display shows the current space heating cooling set temperature of the installation 12 SETTING Not used For installation purposes only 13 NOT AVAILABLE n This icon is displayed whe...

Страница 6: ...orage set point of the domestic hot water temperature only for 4 03 4 or 5 The buttons are not used when the domestic hot water tank is not installed 34 QUIET MODE BUTTON s This button enables or disa...

Страница 7: ...int upon user request 2 Reheat Scheduled The unit will heat up the domestic water tank starting from a scheduled time and untill the reheat set point is reached Preferally this is done during the time...

Страница 8: ...ng operation 1 Press v for 5 seconds to activate powerful domestic water heating operation For EKHW only Icons w and m start flashing 1 For EKHTS only Icons w and start flashing 2 Powerful domestic wa...

Страница 9: ...iquid refrigerant temperature u The outdoor temperature w The domestic hot water temperature INFORMATION Only use the pr button to enable or disable the schedule timer The schedule timer overrules the...

Страница 10: ...m at the very end of this manual This form can help you define the required actions for each day Keep in mind that In the space heating and domestic water heating program 4 actions can be programmed p...

Страница 11: ...e programming mode 8 Use the button to select the action number you would like to program or to modify 9 Use the ba button to select For space heating x switch heating and the controller off 9 set the...

Страница 12: ...select For space cooling x switch cooling and the controller off 9 set the temperature by means of the bi and bj buttons a to select automatic temperature calculation For quiet mode and booster heater...

Страница 13: ...button The actual mode is blinking 2 Use the pi and pj buttons to select the mode you want to program The selected mode is blinking You can leave programming by pressing the pr button 3 Press the but...

Страница 14: ...n 6 Repeat step 2 through 4 to change other field settings as required 7 When finished press the z button to exit FIELD SET MODE Detailed description 0 User permission level If required certain user i...

Страница 15: ..._Ti the target outgoing water temperature when the outdoor temperature equals or rises above the high ambient temperature Hi2_A Note that the Hi2_Ti value should be lower than Lo2_Ti as for warmer out...

Страница 16: ...nt hysteresis Example 1 Scheduled storage 6 03 1 scheduled reheat 6 05 1 disinfection function 2 01 1 activated A Scheduled storage operation activated at 6 04 heat up domestic hot water untill domest...

Страница 17: ...ng automatic storage during night default setting If it seems that the domestic hot water night storage operation is not sufficient for your needs an additional scheduled reheat during daytime can be...

Страница 18: ...it refer to the installation manual of that kit d Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case...

Страница 19: ...n All 01 Status 1 ON 0 1 02 Start time 23 00 0 00 23 00 1 00 hour 03 Set point only in combination with domestic hot water tank without electrical booster heater EKHTS 60 fixed 5 C 03 Set point only i...

Страница 20: ...related setting 9 Heating and cooling set point ranges 00 Heating set point upper limit 55 37 55 1 C 01 Heating set point lower limit 25 15 37 1 C 02 Cooling set point upper limit 22 18 22 1 C 03 Coo...

Страница 21: ...Unit information readout 00 Software version Read only 01 EEPROM version Read only 02 Unit model identification Do not change the default value depending on model 03 Liquid refrigerant temperature Re...

Страница 22: ...nt of oil and other parts must be done by a qualified installer in accordance with the applicable legislation Units must be treated at a specialized treatment facility for re use recycling and recover...

Страница 23: ......

Страница 24: ...4PW62573 1 10 2010 Copyright 2010 Daikin...

Отзывы: