7 Installation
Installer reference guide
45
ERLQ004~008CA + 26CB6W
Daikin Altherma – Low temperature split
4P449978-1B – 2018.07
Backup heater
type
Connections to
backup heater power
supply
Connections to
terminals
6 kW 3N~ 400 V
(*6W)
F1B
L1 L2 L3
L1 L2 L3
1 2 3 4
6 7 8
5
X6M
X7M
Special remark for fuses:
Special remark for terminals:
As mentioned on the table above, the connections on the terminals
X6M and X7M need to be changed to configure a backup heater.
Refer to the illustration below as a caution about handling the
terminals.
3
Fix the cable with cable ties to the cable tie mountings.
4
Configure the user interface for the respective power supply.
See
"8.2.2 Quick wizard: Standard" on page 51
During connection of the backup heater, miswiring is possible. To
detect possible miswiring, it is highly recommended to measure the
resistance value of the heater elements. Depending on the different
backup heater types, following resistance values (see table below)
should be measured. ALWAYS measure the resistance on the
contactor clamps K1M, K2M, and K5M.
3 kW
1~ 230 V
6 kW
1~ 230 V
6 kW
3~ 230 V
6 kW
3N~
400 V
K1M/1
K5M/13
52.9Ω
52.9Ω
52.9Ω
∞
K1M/3
∞
∞
∞
105.8Ω
K1M/5
∞
∞
∞
105.8Ω
3 kW
1~ 230 V
6 kW
1~ 230 V
6 kW
3~ 230 V
6 kW
3N~
400 V
K1M/3
K1M/5
26.5Ω
26.5Ω
26.5Ω
105.8Ω
K2M/1
K5M/13
∞
26.5Ω
26.5Ω
∞
K2M/3
∞
∞
∞
52.9Ω
K2M/5
∞
∞
∞
52.9Ω
K2M/3
K2M/5
52.9Ω
52.9Ω
52.9Ω
52.9Ω
K1M/5
K2M/1
∞
∞
∞
∞
Example measure resistance between K1M/1 and K5M/13:
K1M
K2M
K2M
1 3 5 13
2 4 6 14
K5M
1 3 5 13
2 4 6 14
1 3 5 13
2 4 6 14
Ω
Ω
7.9.9
To connect the user interface
▪ If you use 1 user interface, you can install it at the indoor unit (for
control close to the indoor unit), or in the room (when used as
room thermostat).
▪ If you use 2 user interfaces, you can install 1 user interface at the
indoor unit (for control close to the indoor unit) + 1 user interface
in the room (used as room thermostat).
The procedure differs slightly depending on where you install the
user interface.
#
At the indoor unit
In the room
1
Connect the user interface cable to the indoor unit.
Fix the cable with cable ties to the cable tie mountings.
X2M
X5M
A2P
A2P
2
1
a
b
a
Main user interface
(a)
b
Optional user interface