background image

3 Operation

Operation manual

5

08S23DAV
Daikin Altherma – Low temperature split
4P499572-1 – 2017.06

Item

Description

 User settings

Gives access to user settings such as
holiday mode and quiet mode.

 Information

Displays data and information about the
indoor unit.

 Installer settings

Restriction: 

Only for the installer.

Gives access to advanced settings.

 Commissioning

Restriction: 

Only for the installer.

Perform tests and maintenance.

 User profile

Change the active user profile.

 Operation

Turn heating(/cooling) functionality and
domestic hot water preparation on or off.

INFORMATION

The  Operation  functionality  is  available  in  two  separate
locations. 

Example: 

You  can  enable  the  space  heating(/

cooling) functionality from these two locations in the menu:

▪ Space heating/cooling > Operation [4.1]

▪ Operation > Space heating/cooling [C.2]

3.2.3

Setpoint screen

The  setpoint  screen  is  displayed  for  screens  describing  system
components that need a setpoint value.

Example:

▪ Room temperature screen

▪ Main zone screen

▪ Additional zone screen

▪ Tank temperature screen

a1

d

+

d

e

d

e

c

a2

b1

b2

Go through the list of the submenu.

Go to the submenu.

Adjust and automatically apply the desired
temperature.

Item

Description

Minimum temperature limit

a1

Fixed by the unit

a2

Restricted by the installer

Maximum temperature limit

b1

Fixed by the unit

b2

Restricted by the installer

Current temperature

c

Measured by the unit

Desired temperature

d

Turn the right dial to
increase/decrease.

Submenu

e

Turn or press the left dial to
go to the submenu.

3.2.4

Detailed screen with values

a

b

a

Settings

b

Values

Go through the list of settings.

Confirm changes and proceed.

Change the value.

Go to the next setting.

3.3

Space heating control

3.3.1

Setting the space operation mode

About space operation modes

This unit is a heating only model. The system can heat up a space,
but NOT cool down a space.

3.3.2

To change the desired room temperature

During room temperature control, you can use the room temperature
setpoint screen to read out and adjust the desired room temperature.

1

Go to the [1]: Room menu.

You can read out the desired and actual room
temperature in the center of the setpoint screen.

2

Turn the right dial to adjust the desired room
temperature.

3.3.3

To change the desired leaving water
temperature

INFORMATION

The  leaving  water  is  the  water  that  is  sent  to  the  heat
emitters.  The  desired  leaving  water  temperature  is  set  by
your  installer  in  accordance  with  the  heat  emitter  type.
Only adjust the leaving water temperature settings in case
of problems.

You  can  use  the  leaving  water  temperature  setpoint  screen  to  read
out and adjust the desired leaving water temperature.

1

Go to the 2: Main zone or 3:Additional zone menu.

You can read out the desired and actual leaving
water temperature in the center of the setpoint
screen.

2

Turn the right dial to adjust the desired leaving water
temperature.

3.4

Domestic hot water control

3.4.1

Reheat mode

In  reheat  mode  the  DHW  tank  continuously  heats  up  to  the
temperature shown on the home screen (example: 50°C).

t

60°C

00:00

07:00

50°C

15°C

40°C

14:00

21:00

1

2

3

4

Tt

T

t

DHW tank temperature

t

Time

Содержание EHVH04S23DAG

Страница 1: ...Operation manual Daikin Altherma Low temperature split English Operation manual Daikin Altherma Low temperature split EHVH04S23DAV G EHVH08S23DAV G...

Страница 2: ...e installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future...

Страница 3: ...screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user permission level User or Advanced user 15 min Installer 1 h Dials...

Страница 4: ...dditional zone h3 h1 h2 h1 Heat emitter type Underfloor heating Fancoil unit Radiator h2 Leaving water temperature setpoint h3 Room thermostat type External control Hidden Leaving water temperature co...

Страница 5: ...ubmenu e Turn or press the left dial to go to the submenu 3 2 4 Detailed screen with values a b a Settings b Values Go through the list of settings Confirm changes and proceed Change the value Go to t...

Страница 6: ...ge The amount of information you can read out in the menu structure depends on your user permission level User Standard mode Advanced user You can read out more information 3 5 1 To change the user pe...

Страница 7: ...opy Edit Copy Result C is displayed next to the copied day 3 Select Tuesday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 4 Select Paste Copy Paste C Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C...

Страница 8: ...on manual 8 EHVH04 08S23DAV Daikin Altherma Low temperature split 4P499572 1 2017 06 2 Select the Rename option Delete Rename 3 Browse through the character list and confirm the selected character 4 C...

Страница 9: ...file 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electricity price High Medium Low Schedule 7 2 Time date Hours Minutes AM PM Year Month Day Daylight savings time Format 8 Infor...

Страница 10: ...ode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a preset value Storage comfort higher DHW t...