background image

Table of Contents

Operation manual

2

08S23DAV

Daikin Altherma – Low temperature split

4P499572-1 – 2017.06

Table of Contents

1 About this document

2

2 About the system

2

2.1

Components in a typical system layout .....................................

3

3 Operation

3

3.1

User interface: Overview ...........................................................

3

3.2

Possible screens: Overview ......................................................

3

3.2.1

Home screen...............................................................

4

3.2.2

Main menu screen ......................................................

4

3.2.3

Setpoint screen ...........................................................

5

3.2.4

Detailed screen with values ........................................

5

3.3

Space heating control................................................................

5

3.3.1

Setting the space operation mode ..............................

5

3.3.2

To change the desired room temperature...................

5

3.3.3

To change the desired leaving water temperature......

5

3.4

Domestic hot water control ........................................................

5

3.4.1

Reheat mode ..............................................................

5

3.4.2

Scheduled mode .........................................................

6

3.4.3

Sch reheat mode...........................................

6

3.4.4

Using DHW powerful operation...................................

6

3.5

Advanced usage........................................................................

6

3.5.1

To change the user permission level ..........................

6

3.6

Schedule screen: Example........................................................

6

3.7

Menu structure: Overview user settings ....................................

9

3.8

Installer settings: Tables to be filled in by installer ....................

10

3.8.1

Configuration wizard ................................................... 10

3.8.2

Settings menu ............................................................. 10

4 Energy saving tips

10

5 Maintenance and service

10

5.1

Overview: Maintenance and service .........................................

10

5.2

To find the contact/helpdesk number ........................................

11

6 Troubleshooting

11

6.1

To display the help text in case of a malfunction.......................

11

6.2

Symptom: You are feeling too cold (hot) in your living room.....

11

6.3

Symptom: The water at the tap is too cold ................................

11

6.4

Symptom: Heat pump failure .....................................................

11

7 Disposal

11

8 Glossary

12

1

About this document

Thank you for purchasing this product. Please:

▪ Read  the  documentation  carefully  before  operating  the  user

interface to ensure the best possible performance.

▪ Request the installer to inform you about the settings that he used

to  configure  your  system.  Check  if  he  has  filled  in  the  installer
settings tables. If not, request him to do so.

▪ Keep the documentation for future reference.

Target audience

End users

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety  instructions  that  you  must  read  before  operating  your

system

▪ Format: Paper (in the box of the indoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the indoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

Breadcrumbs

Breadcrumbs help you to locate where you are in the menu structure
of the user interface.

1

To 

enable

 the breadcrumbs: In the home screen or

main menu screen, press the help button. The
breadcrumbs will appear in the top left corner of the
screen.

2

To 

disable

 the breadcrumbs: Press the help button

again.

This document also mentions these breadcrumbs. 

Example:

1

Go to [4.4]: Space heating/cooling > Operation
range.

This means:

▪ Starting  from  the  home  screen,  turn  the  left  dial

and go to Space heating/cooling.

▪ Press the left dial to enter the submenu.

▪ Turn the left dial and go to Operation range.

▪ Press the left dial to enter the submenu.

4

4.4

Operation range

Operation range

2

About the system

Depending on the system layout, the system can:

▪ Heat up a space

▪ Produce domestic hot water

Содержание EHVH04S23DAG

Страница 1: ...Operation manual Daikin Altherma Low temperature split English Operation manual Daikin Altherma Low temperature split EHVH04S23DAV G EHVH08S23DAV G...

Страница 2: ...e installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future...

Страница 3: ...screen darkens Pressing any button or rotating any dial awakens the display The time of non interaction differs depending on the user permission level User or Advanced user 15 min Installer 1 h Dials...

Страница 4: ...dditional zone h3 h1 h2 h1 Heat emitter type Underfloor heating Fancoil unit Radiator h2 Leaving water temperature setpoint h3 Room thermostat type External control Hidden Leaving water temperature co...

Страница 5: ...ubmenu e Turn or press the left dial to go to the submenu 3 2 4 Detailed screen with values a b a Settings b Values Go through the list of settings Confirm changes and proceed Change the value Go to t...

Страница 6: ...ge The amount of information you can read out in the menu structure depends on your user permission level User Standard mode Advanced user You can read out more information 3 5 1 To change the user pe...

Страница 7: ...opy Edit Copy Result C is displayed next to the copied day 3 Select Tuesday Mon Sat Wed Fri Thu Tue Sun User defined 1 C 4 Select Paste Copy Paste C Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C...

Страница 8: ...on manual 8 EHVH04 08S23DAV Daikin Altherma Low temperature split 4P499572 1 2017 06 2 Select the Rename option Delete Rename 3 Browse through the character list and confirm the selected character 4 C...

Страница 9: ...file 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule 7 5 Electricity price High Medium Low Schedule 7 2 Time date Hours Minutes AM PM Year Month Day Daylight savings time Format 8 Infor...

Страница 10: ...ode Tips about DHW tank temperature Use a weekly schedule for your normal domestic hot water needs only in scheduled mode Program to heat up the DHW tank to a preset value Storage comfort higher DHW t...

Страница 11: ...r type 6 3 Symptom The water at the tap is too cold Possible cause Corrective action You ran out of domestic hot water because of unusual high consumption If you immediately need domestic hot water ac...

Страница 12: ...3DAV Daikin Altherma Low temperature split 4P499572 1 2017 06 8 Glossary DHW Domestic hot water Hot water used in any type of building for domestic purposes LWT Leaving water temperature Water tempera...

Страница 13: ......

Страница 14: ......

Страница 15: ......

Страница 16: ...4P499572 1 2017 06 Copyright 2017 Daikin 4P499572 1 0000000Y...