32
32
cool SetUP
SUBMENU ITEM
USER MODIFIABLE OPTIONS
COMMENTS
CL Reset
YES or NO
Selecting to default factory setting.
Cool Airflow Trim Hi
-15% to +15% in 3% increments
Selects the cooling airflow trim amount.
Cool Airflow Trim Int
-15% to +15% in 3% increments
Selects the cooling airflow trim amount.
Cool Airflow Trim Low
-15% to +15% in 3% increments
Selects the cooling airflow trim amount.
Cool Airflow Profile
A, B, C, or D
Selects the cooling airflow profile.
Cool ON Delay
5, 10, 20, 30 seconds
Selects the indoor blower ON delay.
Cool OFF Delay
30, 60, 90, 120 seconds
Selects the indoor blower OFF delay.
Dehumidification Select
ON or OFF
Selecting “OFF” disables dehumidification; selecting
“ON” enables dehumidification.
Set coolinG rUn vAlUeS (cl rUn vAlUeS)
SUBMENU ITEM
USER MODIFIABLE OPTIONS
COMMENTS
Maximum Compressor RPS Range
for Cooling
(COOL RPS RANGE)
Five different compressor RPS
ranges will be provided.
Select the appropriate range for the installed system
configuration.
Maximum Compressor RPS Selec
-
tion for Cooling
(COOL RPS SELECT)
10 compressor RPS values will be
provided within the range selected
in the COOL RPS RANGE menu.
Select the appropriate compressor RPS for the
installed system configuration.