Daikin DST301BA61 Скачать руководство пользователя страница 10

7

(2) Set the next day of the week.

Set the day of the week to Tuesday, and 

copy the program of the previous day 

(Monday).  In the same procedure, set the 

day of the week to Wednesday through Fri-

day in sequence.

6.

Press the BUTTON FOR 

SELECTING DAYS OF A WEEK 

and set the following day.  Press 

the BUTTON FOR COPYING PRO-

GRAM OF PREVIOUS DAY. The 

same program as that of the imme-

diately preceding day of the week 

is set.

(NOTE)

• Repeat each procedure 3 – 5 in the 

above when not copying the contents of 
the previous day.

(3) Holiday setting

7.

Press the BUTTON FOR 

SELECTING DAYS OF A WEEK 

and set one or more days of the 

week as holiday.  Press the HOLI-

DAY SETTING BUTTON, and the 

display “ OFF ” is displayed at the 

top of the day of the week.  If you 

press it again, the display returns 

to the original state.

8.

Press the PROGRAMMING 

START BUTTON, and finish the 

program setting.

(NOTES)

• Unless the button is pressed within 20 

minutes, the display will automatically 
revert back to the original state. In this 
case, setting contents up to the point 
where the TIMER ON BUTTON (or HOL-
IDAY SETTING BUTTON or BUTTON 
FOR COPYING PROGRAM OF PREVI-
OUS DAY) is pressed will only take 
effect.

• The display “ PROGRAM   

START ” 

and the display of days of a week “ — ” 
disappears.

• The flashing display goes off, and the 

No. of programmed time of the present 
day is displayed.  Then the operation 
controlled by timer starts.

• The operation controlled by timer is exe-

cuted even while the program is being 
set.

„

„

„

„

Change and cancellation of no. 
of programmed time (Fig. 5)

(Example)

Time No. 3 (to be set only when 

used in conjunction with the 

central remote controller)

1.

Press the PROGRAMMING 

START BUTTON.  The program 

setting is ready.  The display 

“ PROGRAM  

START ” appears, 

and the display of days of a week 

flashes.

2.

Press the TIME No. BUTTON, 

and select the desired No.

6

7

Set Saturday and Sunday as holidays.

8

This is the end of the setting example.

Operating from
8:45 a.m. till
5:00 p.m.

A: Change/
cancel partially

(Wednesday)
After operating 
from 8:45 a.m. 
till 7:00 p.m., 
the operation 
stops.

Operating from
5:15 p.m. till
11:00 p.m.

B: Cancel the 
whole

(Thursday)
Whole day 
stop.

1

2

Select the time No. 3.

01_EN_3P124623-5C.fm  Page 7  Wednesday, August 3, 2005  2:20 PM

Содержание DST301BA61

Страница 1: ...timer For proper usage read this manual carefully before using this unit This manual will help you with anything you can not understand or should anything go wrong with the unit during use Keep this manual handy for the future reference 00_CV_3P124623 5C fm Page 1 Saturday July 30 2005 8 10 PM ...

Страница 2: ... 1 1 2 3 6 4 9 7 8 10 11 5 DST301BA61 17 15 14 12 13 18 19 20 16 DST301BA61 1 2 00_CV_3P124623 5C_2 fm Page 1 Wednesday August 3 2005 4 53 PM ...

Страница 3: ... 2 1 2 3 4 DST301BA61 7 3 2 1 8 6 4 5 DST301BA61 7 6 2 3 7 1 8 5 4 5 6 DST301BA61 DST301BA61 3 7 5 4 6 00_CV_3P124623 5C_2 fm Page 2 Wednesday August 3 2005 4 53 PM ...

Страница 4: ...enance Incomplete improvement repair and main tenance may result in a water leakage elec tric shock and fire Improper installation or attachment of equipment or accessories could result in electric shock short circuit leaks fire or other damage to the equipment Be sure only to use accessories made by Daikin which are specifically designed for use with the equipment and have them installed by a pro...

Страница 5: ... cause stabs or other injuries Tear apart and throw away plastic packaging bags so that children will not play with them If children play with a plastic bag which was not torn apart they face the risk of suffocation Do not turn off the power immediately after stopping operation Always wait at least five minutes before turn ing off the power Otherwise water leakage and trouble may occur The applian...

Страница 6: ...sory The operation controlled by programmed time can be set for up to eight different patterns timer No 1 8 Each schedule pattern can be also selected n Operation controlled by programmed time Operating time and stopping time can be set to the minute by each day of the week The operating and stopping patterns can also be set in schedule according to the time slot given twice a day in tune with the...

Страница 7: ...ay 7 DISPLAY SETTING OF DAYS OF A WEEK Flashes below the day of the week pro grammed 8 DISPLAY MALFUNC TION CODE Displays the contents of malfunction during the stop due to malfunction 9 DISPLAY PRESENT TIME Displays the present day of the week and time 10 DISPLAY PRO GRAMMED TIME OF SYSTEM START Displays the time programmed to start 11 DISPLAY PRO GRAMMED TIME OF SYSTEM OFF Displays the time prog...

Страница 8: ...ashes and the clock starts NOTES The clock used is of 12 hour type When you turn power supply on the sys tem may display for about one minute and not start to operate after all the liquid crystal displays appear at a time If the CLOCK ADJUSTING BUTTON is pressed by mistake press it again to return to the original state As the clock does not stop the time indicated by the clock is kept correct In c...

Страница 9: ...ot displayed and can not be selected 3 Press the BUTTON FOR SELECTING DAYS OF A WEEK and set the proper day of the week Each time you press it the flash ing display of days of a week shifts to the right 1 Setting programmed time 4 Set the programmed time of system start 1 by using the HOUR MINUTE BUTTON Each time the HOUR MINUTE BUTTON is pressed the display is put forward minute by minute and hou...

Страница 10: ...tting contents up to the point where the TIMER ON BUTTON or HOL IDAY SETTING BUTTON or BUTTON FOR COPYING PROGRAM OF PREVI OUS DAY is pressed will only take effect The display PROGRAM START and the display of days of a week disappears The flashing display goes off and the No of programmed time of the present day is displayed Then the operation controlled by timer starts The operation controlled by...

Страница 11: ...TON to finalize the cancella tion In the same procedure cancel the programmed time of system off 2 B Cancel the whole 7 Press the BUTTON FOR SELECTING DAYS OF A WEEK and shift to the day of the week to be canceled Then press the HOL IDAY SETTING BUTTON the dis play OFF appears at the top of the particular day of the week The programmed time is canceled If you press the button again the display ret...

Страница 12: ...nder operation control may be turned on or off a few minutes behind schedule This shows that the signal is being exchanged and does not indicate any failure Operation control code Two different types of operation control codes can be selected when this kit is used indepen dently when not used in conjunction with the central remote controller unified ON OFF con troller etc Individual In case where ...

Страница 13: ...dress failure of schedule timer Fixes The following causes are possible Check each one 1 Do the control rangeaddresses in the central remote control ler overlap 2 Do the control rangeaddresses in the on off con troller overlap 3 Are there 2 or more schedule timers con nected Flash UE Malfunction of transmission between indoor unit and optional controllers for cen tralized control Fixes Inspect all...

Страница 14: ...troller set for on at the same time If two timer numbers are set make sure that the settings for holidays and working days do not overlap between the different timer numbers The TIME NO is not displayed The following causes are possible 1 The TIME NO is not displayed when using the schedule timer alone It can be set if using the central remote controller at the same time The display remains even t...

Страница 15: ...perature from 15 C to 35 C Timer programming Two pairs of programmed time for both system start and system off can be set in units of minute for each day of the week Power failure compensation time Approximately 48 hours for a single occurrence of power failure clock with No of programmed time Size 120 W 120 H 53 D mm Width Height Depth Weight Approximately 210g 120 16 37 71 120 01_EN_3P124623 5C ...

Страница 16: ...3P124623 5C EM05A041 0509 HT 00_CV_3P124623 5C fm Page 2 Saturday July 30 2005 8 10 PM ...