background image

14

www.daikincomfort.com

SS-DM96SE

SS-DM96SE

www.daikincomfort.com

15

Wiring Diagram

Wirin

g is sub

ject t

o chan

ge. Alw

ay

re

fer t

o the wirin

g d

iagr

am on th

unit f

or the mos

t u

p-t

o-d

at

e wiring.

  

W

arning

High V

olt

age:

 

Disc

onn

ect 

all 

po

w

er 

be

for

ser

vicin

or 

in

st

allin

th

is 

unit. 

Mu

lti

ple 

po

w

er

 

 

sou

rces ma

y be p

resen

t. F

ailu

re t

o d

o so ma

y c

au

se p

rop

erty d

amag

e, p

er

sonal in

ju

ry

, or d

ea

th

.

YL YELLOW

OR ORANGE
PU PURPLE

GR GREEN

BK BLACK

BR BROWN

WH WHITE

BL BLUE

GY GRAY

RD RED

COLOR CODES:

LOW VOLTAGE (24V)

LOW VOLTAGE FIELD

HI VOLTAGE (115V)

HI VOLTAGE FIELD

NOTES:

1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.

2. MANUFACTUR'S SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.

GAS VALVE

C2

INTERNAL TO

INTEGRATED CONTROL

JUNCTION

EQUIPMENT GND

FIELD GND

DIAGNOSTIC

LED

2 CIRCUIT

CONNECTOR

HOT

SURFACE

IGNITER

OVERCURRENT

PROT. DEVICE

IGNITER

TH (3)

INTEGRATED

CONTROL MODULE

JUNCTION BOX

LINE-H

XFMR-H

INT

EG

RA

TE

D CO
NT

RO

L M

OD

UL

E

INT

EG

RA

TE

D C

ONT

RO

L M

ODU

LE

GND

DISCONNECT

L

N

DISCONNECT POWER

BEFORE SERVICING.

WIRING TO UNIT

MUST BE

PROPERLY

POLARIZED

AND GROUNDED.

OVERCURRENT PROTECTION DEVICE

BL

4. BLOWER SPEEDS SHOULD BE ADJUSTED BY INSTALLER TO MATCH THE INSTALLATION REQUIREMENTS SO

AS TO PROVIDE THE CORRECT HEATING TEMPERATURE RISE AND THE CORRECT COOLING CFM.

3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE REPLACED, IT MUST BE

HAVING A TEMPERATURE RATING OF AT LEAST

TERMINAL

SWITCH (PRESS.)

5. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C. AND LOCAL CODES.

PK PINK

FLAME

SENSOR

( SINGLE CONTROL ON 40K BTU )

BK

PLUG CONNECTION

FIELD SPLICE

SWITCH (TEMP.)

BLOWER

COMPARTMENT

DOOR SWITCH

(OPEN WHEN

DOOR OPEN)

DOOR

SWITCH

WARNING:DISCONNECT POWER BEFORE

SERVICING.WIRING TO UNIT MUST BE

PROPERLY POLARIZED AND GROUNDED.

POW

ER SU

PPL

Y WIT

H

OVERCUR

RENT

 PRO

TECT

ION

DEVICE

1

TO 115

 VAC /

 1Ø / 6

0HZ

OR

ID BLOWER

PRESSURE

SWITCH

RD

WH

BURNER COMPARTMENT

BLOWER COMPARTMENT

NO

YL

CONTROL

PRIMARY LIMIT

AUTO RESET

BL

PU

MANUAL RESET ROLLOUT LIMIT CONTROL(S)

RD

OR

PK

BK

WH

WH

BLOWER

INDUCED DRAFT

AUXILIARY

LIMIT

CONTROLS

C

FS

LIMIT CONTROLS

AUXILIARY

IGNITER

HOT SURFACE

IND

IGN

BLWR

CIRCULATOR

BLWR

ID

FLAME SENSOR

115 VAC

TRANSFORMER

40 VA

24 VAC

GND

CONTROL

LIMIT

PRIMARY

AUTO RESET

(SINGLE CONTROL ON 40K BTU)

LIMIT CONTROL(S)

MANUAL RESET ROLLOUT

RO1 (5)

RO2 (11)

HLO (1)

HLI (7)

MVC (9)

GND (8)

TR (6)

OR

WH

BL

YL

OR

RD

GR

BR

PK

PK

BK

BK

24V 

TH

ER

MO

ST

AT

 C

ON

NEC

TIO

NS N

.E.

C. C

LASS 2

 W

IR

E

MICRO

TO

C

G

Y

W

R

2

OR

BL

YL

OR

PK

RD

OR

WH

XF

MR-

H

BL

GY

GR

1

2

3

12

11

10

9

8

7

6

5

4

WARNING:

105°C. USE COPPER CONDUCTORS ONLY.

PSO (4)

MV(12)

PS (10)

C

NO

ID BLOWER

PRESSURE

SWITCH

0

C

6

5

4

3

2

1

OFF

= CONTROL FAILURE

STEADY ON = NORMAL OPERATION

1 FLASH

=

2 FLASHES = PRESSURE SWITCH STUCK CLOSED
3 FLASHES = PRESSURE SWITCH STUCK OPEN

4 FLASHES = OPEN HIGH LIMIT

5 FLASHES = FLAME SENSE WITHOUT GAS VALVE

OPEN ROLLOUT

6 FLASHES =

SYSTEM LOCKOUT (RETRIES EXCEEDED)

CONTINUOUS/RAPID FLASHES = REVERSED 115 VAC POLARITY

CONTROL

MODULE

INTEGRATED

FUSE

MI

GY

GY

M1

GAS

VALVE

C2

TO 115VAC/ 1 Ø /60 HZ POWER SUPPLY WITH

PU

BR

GY

BR

LIN

E NE

UT

RA

LS

NO

C

FRONT COVER

PRESSURE SWITCH

C

N

O

FRONT COVER

PRESSURE SWITCH

YL

7 FLASHES =
8 FLASHES =

LOW FLAME SIGNAL

IGNITER RELAY FAULT

7

8

ELECTRONIC

AIR CLEANER

EAC-H

HUMIDIFIER

HUMIDIFIER

R

C G

W Y

24V THERMOSTAT

CONNECTIONS

N.E.C. CLASS 2 WIRE

RD

OR

115 VAC

24 VAC

BK

GY

40 VA

TRANSFORMER

WH

GR

GND

RD

5

2

1

4

3

G

C

WH

L

N

BLOWER

CIRCULATOR

HARNESS

ECM MTR

RD BK

OR

BL

BK

RD

WH

WH

WH

BL

RD

OR

BK

WH

BK

GND

DISCONNECT

L

N

WH

JUNCTION BOX

GND

GR

GR

GND

GND

E9

E36

IGN-N

IGN-N

IGN-N

E8

120V

E7

HUM-N

E6

IGN-N

E5

XFMR-N

IGN-N

E4

E32

E25

E3

E1

E2

LINE-H XFMR-H CIRC-H 120V

HUM-H EAC-H

T1 T2 T3 T4 X COM

BK

R C

MICRO

CONTROLLED

0140F02509-A

9 FLASHES =

9

10 FLASHES =

10

11 FLASHES =

11

12 FLASHES =

12

REPLACED WITH WIRING MATERIAL

TWINNING FAULT

OPEN FUSE

IGNITER OPEN
INDUCER RELAY ERROR / IMPROPER GROUNDING

BK

CIRC-H

Содержание DC96SE 0403BN

Страница 1: ...rd Features Cabinet Features Heavy duty stainless steel tubular heat exchanger Stainless steel secondary heat exchanger Single stage gas valve Durable Silicon Nitride igniter Multi speed blower motor Self diagnostic control board with constant memory fault code history output to a LED California Low NOx emissions compliant models available Can no longer be installed in California s South Coast Air...

Страница 2: ... Downflow Horizontal A Initial Release B 1st Revision AFUE 97 97 98 AFUE 92 92 AFUE NOx 96 96 AFUE N Low Nox 40ng J Gas Valve Cabinet Width M Modulating A 14 V Two Stage S Single Stage B 17 C 21 Motor D 24 C Variable Speed ECM Communicating E Multi Speed ECM S Multi Speed PSC Maximum CFM 2 800 CFM MBTU h 3 1200 CFM 040 40 000 BTU h 100 100 000 BTU h 4 1600 CFM 060 60 000 BTU h 120 120 000 BTU h 5 ...

Страница 3: ...ch 1000 above 4500 altitude DOE AFUE based upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canada CAN CSA B149 1 and CAN CSA B142 2 in Canada Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire...

Страница 4: ...ertified NO NO NO NO NO Natural Gas BTU h for altitudes 0 4500 above sea level reduce input rating by 4 for each 1000 above 4500 altitude DOE AFUE based upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada Minimum Circuit Ampacity 1 25 x Circ...

Страница 5: ...20 19 20 5 9 19 34 19 B C 23 2 1 2 2 6 5 9 19 23 24 31 A 21 2 14 23 1 1 287 8 2 1 2 2 2 6 1 26 23 Folded Flanges 22 Unfolded Flanges D Unfolded Flanges E Folded Flanges Air Discharge Air Discharge LEFT SIDE VIEW FRONT VIEW RIGHT SIDE VIEW Condensate Drain Trap Exterior Connection Right or Left Side PVC Vent Flue Pipe 2 PVC Alternate Vent Flue Location Right Side Drain Trap Exterior Holes High Volt...

Страница 6: ...or Drain Trap Holes Low Voltage Electrical Outlet Air Discharge Air Discharge Folded Flanges B 18 Minimum Clearances to Combustible Materials Position Sides Rear Front Bottom Flue Top Downflow 0 0 3 NC 0 1 Horizontal 6 0 3 C 0 6 C If placed on combustible floor the floor MUST be wood ONLY NC For installation on non combustible floors only A combustible floor sub base must be used for installations...

Страница 7: ...3 N A 800 N A 715 N A 627 561 496 ON OFF 1826 49 1783 50 1730 51 1685 53 1642 54 1596 1548 1504 ON ON 1465 N A 1402 N A 1360 N A 1306 N A 1250 N A 1197 1138 1073 OFF ON 1602 55 1556 57 1510 59 1460 N A 1411 N A 1372 1315 1261 DM96SE 1205D OFF OFF 1121 N A 1018 N A 933 N A 839 N A 762 N A 671 592 519 ON OFF 1969 54 1913 56 1862 57 1807 59 1756 61 1705 1647 1599 ON ON 1688 63 1626 N A 1564 N A 1500 ...

Страница 8: ... ON 2215 2171 2137 2098 2060 2022 1986 1948 1908 1869 DM96SE 1005C OFF OFF 1012 940 863 800 715 627 561 496 437 374 ON OFF 1826 1783 1730 1685 1642 1596 1548 1504 1455 1406 OFF ON 1602 1556 1510 1460 1411 1372 1315 1261 1207 1156 ON ON 2225 2180 2141 2105 2070 2033 1996 1957 1923 1883 DM96SE 1205D OFF OFF 1121 1018 933 839 762 671 592 519 447 371 ON OFF 1969 1913 1862 1807 1756 1705 1647 1599 1544...

Страница 9: ...10 935 861 785 721 631 553 483 423 350 ON OFF ON 1010 935 861 785 721 631 553 483 423 350 ON ON ON 1010 935 861 785 721 631 553 483 423 350 ON OFF OFF 1621 1570 1521 1467 1414 1378 1327 1274 1221 1167 ON ON OFF 1439 1400 1347 1291 1234 1182 1125 1065 1000 930 OFF ON OFF 1826 1775 1726 1684 1634 1588 1538 1492 1448 1398 OFF OFF ON 1843 1798 1753 1710 1666 1618 1574 1526 1481 1432 DM96SE 0805C OFF O...

Страница 10: ...1205D OFF OFF 1296 N A 1190 N A 1076 N A 960 N A 839 N A 760 653 559 ON OFF 1917 56 1843 58 1759 61 1686 63 1600 67 1513 1420 1348 ON ON 1611 66 1521 70 1433 74 1347 N A 1246 N A 1145 1044 953 OFF ON 2011 N A 1936 N A 1858 N A 1779 N A 1692 N A 1610 1531 1442 at 0 5 ESP Notes CFM in chart is without filter s Filters do not ship with this furnace but must be provided by the installer If the furnace...

Страница 11: ...5 OFF ON 2230 2176 2125 2086 2038 1999 1958 1917 1880 1829 DC96SE 1205D OFF OFF 1296 1190 1076 960 839 760 653 559 452 351 ON OFF 1917 1843 1759 1686 1600 1513 1420 1348 1258 1173 ON ON 2011 1936 1858 1779 1692 1610 1531 1442 1365 1266 OFF ON 2317 2257 2196 2122 2061 1990 1914 1762 1523 1232 at 0 5 ESP Notes CFM in chart is without filter s Filters do not ship with this furnace but must be provide...

Страница 12: ...0 266 224 190 OFF ON ON 760 686 613 542 459 376 310 266 224 190 ON OFF ON 760 686 613 542 459 376 310 266 224 190 ON ON ON 760 686 613 542 459 376 310 266 224 190 ON OFF OFF 1390 1342 1292 1254 1201 1157 1112 1072 1022 985 ON ON OFF 1397 1361 1318 1266 1224 1181 1139 1095 1050 1003 OFF ON OFF 1581 1537 1492 1452 1413 1387 1347 1305 1267 1225 OFF OFF ON 1800 1758 1716 1678 1636 1601 1565 1529 1491 ...

Страница 13: ...UT BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Temperature Rise Output BTU h x 1 000 Formulas BTU h Output CFM x 1 08 x Rise Rise BTU H Output CFM x 1 08 BTU Output Vs Temperature Rise Chart ...

Страница 14: ...OWER PRESSURE SWITCH RD WH BURNER COMPARTMENT BLOWER COMPARTMENT NO YL CONTROL PRIMARY LIMIT AUTO RESET BL PU MANUAL RESET ROLLOUT LIMIT CONTROL S RD OR PK BK WH WH BLOWER INDUCED DRAFT AUXILIARY LIMIT CONTROLS C FS LIMIT CONTROLS AUXILIARY IGNITER HOT SURFACE IND IGN BLWR CIRCULATOR BLWR ID FLAME SENSOR 115 VAC TRANSFORMER 40 VA 24 VAC GND CONTROL LIMIT PRIMARY AUTO RESET SINGLE CONTROL ON 40K BT...

Страница 15: ...sion Kits Notes Indicates available for this model Indicates 9 001 to 11 000 altitude Indicates 7 001 to 9 000 altitude Indicates 7 001 to 11 000 altitude All installations above 7 000 require a pressure switch change For installation in Canada gas furnaces are certified only to 4 500 Model Description DM96SE 0403AN DM96SE 0603BN DM96SE 0803BN DM96SE 0804CN DM96SE 0805CNA DM96SE 1005CN DM96SE 1205...

Страница 16: ...16 www daikincomfort com SS DM96SE Our continuing commitment to quality products may mean a change in specifications without notice 2021 Houston Texas Notes ...

Отзывы: