SiENBE04-808_A
Outdoor Unit - RK(X)S42G2V1B, ARXS42G2V1B
Removal Procedure
256
4.7
Removal of Four Way Valve / Electronic Expansion Valve
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the peripheries.
Preparation
Remove the sound blanket.
Detach the four way valve
coil and the 2 clamps, and
then detach the wire
harnesses.
1
Remove the screw and
remove the four way
valve coil.
2
Pull out the electronic
expansion valve coil.
3
Remove the putty.
4
Remove the terminal
cover.
(R7703)
(R8203)
(R8204)
(R8205)
(R8195)
Terminal cover