SiENBE04-808_A
Service Check Function
Service Diagnosis
98
Check Method 2
1. Press the 3 buttons (TEMP
s
, TEMP
t
, MODE) at the same time.
The figure of the ten’s place blinks.
2. Press the TEMP
s
or
t
button and change the figure until you hear the sound of “beep” or “pi
pi”.
3. Diagnose by the sound.
H
“pi” : The figure of the ten’s place does not accord with the error code.
H
“pi pi” : The figure of the ten’s place accords with the error code but the one’s not.
H
“beep” : The both figures of the ten’s and one’s place accord with the error code.
(
→
See 7.)
4. Press the MODE button.
The figure of the one’s place blinks.
(R8381)
(R8382)
(R8383)
(R8384)
(R8385)
SiENBE04-808_A.pdf 110
21/02/2011 13:20:01