SiENBE04-808_A
Indoor Unit
Removal Procedure
164
4. Remove the vertical blade
ASSY.
1
Detach the pivot from
the interlock shaft for
vertical blades with a
flat screwdriver.
2
Remove the interlock
rod.
3
Unfasten the hooks at
the upper 3 positions by
pressing them with a
flat screwdriver.
4
Remove the vertical
blade ASSY.
A vertical blade ASSY has 5
fins. It is impossible to
replace only one fin.
The vertical blade ASSY is
not marked for difference
between right and left.
Step
Procedure
Points
(R12270)
Vertical blade ASSY
Pivot
Interlock
shaft
(R10302)
Interlock rod
(R10303)
(R12269)
Hook
SiENBE04-808_A.pdf 176
21/02/2011 13:20:05