17
S
U I
4.13
4.14
4.15
00
E1
E2
E3
Gr
Room temperature probe regulation offset
Switching off for long periods
When switching off for a season or for holidays, proceed
as follows:
- Deactivate the device
- Turn the general unit switch to off.
The antifreeze function is not active.
As the detection probe is towards the bottom of the
device, the temperature detected may at times differ from
the actual room temperature.
By using this function, the value displayed can be adjusted
in a range from -9 to +12 K in intervals of 1°C.
Use this adjustment with care, and only after having
actually detected a discrepancy compared with the actual
room temperature using a reliable device!
Key
Operation
Display
With the display off, press and hold the - key for 5 seconds to access the menu which
allows adjustment (using the + and - keys) of the AIR probe offset displayed, from -9
to +12 K in 1 K intervals.
After 20 seconds from the last action, the panel switches off and the setting is stored.
Error
Display
Faulty room temperature (AIR) probe
Problem with fan motor (e.g. blockage caused by foreign objects, faulty rotation sensor).
Water temperature probe fault.
In this case, ensure that the probe installed is 10 kΩ.
Engaging of grille microswitch S1 due to filter cleaning operation
Error signals