background image

6

S

U I

A

B

2.1 

2.2 

2.3 

A

Display

B

Keys

These controls make room temperature adjustment (with 
offset settable from the keyboard) completely autonomous 
through the AUTO, SILENT, NIGHT and MAX programmes 
by means of a probe located in the lower part of the device, 
ensuring anti-freeze safety even when set to stand-by. 
The control panel has a memory, so settings will not be 
lost if the appliance is switched off or in the power supply 
is cut.

  Controls cannot be installed on the FWXM-series.

  After 20 seconds from the last action the panel 

brightness will be reduced for improved night-time 
comfort, and the room temperature will appear on the 
display. Press any key to restore maximum brightness.

The 10 kΩ water temperature probe positioned in the 
device battery regulations the minimum level when heating 
(30°C) and the maximum level when cooling (20°C).

The various functions are set using 8 backlit keys:

Any statuses and alarms are also shown on the display by 
using 8 specific symbols:

EKRTCTRL1

Automatic operation

Silent operation

Maximum ventilation speed

Night-time operation

Heating on

Cooling on

Supervision on Flashing with presence switch CP 
closed.

Alarm indicator (solid light)

Panel off indicator

Resistance active indicator

Temp + is for increasing the set temperature

Temp - is for decreasing the set temperature

Heating / Cooling: for changing the operation 

mode between heating and cooling

Sets the regulation ventilation speed between 

a minimum and maximum value to an entirely 

automatic mode

Night-time operation: limits ventilation speed 

to a contained level and the set temperature 

is adjusted automatically.

Maximum speed operation: Allows for the 

maximum ventilation speed to be set

ON/Stand-By: for activating the device or for 

putting it in stand-by.

Silent: limits ventilation speed to a more 

contained value

SMART TOUCH electronic control panel with device side continuous modulation

Display

Key function

Содержание Altherma EKRTCTRL2

Страница 1: ...EKRTCTRL1 EKRTCTRL2 EKWHCTRL0 EKWHCTRL1 EKPCBO USER MANUAL Daikin Altherma heat pump convector options...

Страница 2: ...use of the appliance in a rapid unmistakable way Symbols U User Refers to pages containing instructions or information for the user I Installer Refers to pages containing instructions or information...

Страница 3: ...8 2 15 Deactivation 9 2 16 Room temperature probe regulation offset 9 2 17 Switching off for long periods 9 2 18 Error signals 9 3 EKWHCTRL1 3 1 Wall mounted SMART TOUCH electronic control panel with...

Страница 4: ...3 Room temperature probe regulation offset 17 4 14 Switching off for long periods 17 4 15 Error signals 17 5 EKPCBO 5 1 On board speed selector for connecting to standard thermostat 18 5 2 LED indicat...

Страница 5: ...roduct that uses electricity and water such as The unit can be used by children over the age of 8 and by people with reduced physical sensory or mental capabilities or with no experience or necessary...

Страница 6: ...s functions are set using 8 backlit keys Any statuses and alarms are also shown on the display by using 8 specific symbols EKRTCTRL1 Automatic operation Silent operation Maximum ventilation speed Nigh...

Страница 7: ...hese values for brief periods and then set a intermediate value The controller is very precise set it to the required value and wait for the controller to regulate itself according to the actual room...

Страница 8: ...whenever any key is pressed LOC will appear To unlock the keys repeat the sequence Key Operation Display Press and hold the Max Operation key The function being activated is indicated by the relevant...

Страница 9: ...ment using the and keys of the AIR probe offset displayed from 9 to 12 K in 0 1 K intervals After 20 seconds from the last action the panel switches off and the setting is stored The controller also e...

Страница 10: ...also shown on the display by using 8 specific symbols Automatic operation Silent operation Maximum ventilation speed Night time operation Heating on Cooling on Supervision on Flashing with presence s...

Страница 11: ...To activate the device Key Operation Display Keep the Heating Cooling key pressed for approx 2 seconds to change the mode between heating and cooling which is indicated by the 2 symbols that appear if...

Страница 12: ...his is indicated by bL appearing on the display All actions are disabled to the user and whenever any key is pressed LOC will appear To unlock the keys repeat the sequence Key Operation Display Press...

Страница 13: ...vice Key Operation Display With the display off press and hold the key for 5 seconds to access the menu which allows adjustment using the and keys of the AIR probe offset displayed from 9 to 12 K in 0...

Страница 14: ...ng 8 backlit keys Any statuses and alarms are also shown on the display by using 8 specific symbols EKRTCTRL2 Automatic operation in steps Minimum operation Maximum ventilation speed Super silent oper...

Страница 15: ...pened The adjustment range is from 16 to 28 C in intervals of 1 C but out of range values are also accepted from 5 C to 40 C unless in auto mode Only set these values for brief periods and then set a...

Страница 16: ...vated immediately whether heating or cooling Once the desired room temperature is reached we recommend selecting one of the other 3 operation modes for increased comfort and sound levels In minimum mo...

Страница 17: ...stment with care and only after having actually detected a discrepancy compared with the actual room temperature using a reliable device Key Operation Display With the display off press and hold the k...

Страница 18: ...series After 20 seconds from the last action the LED brightness will be reduced for improved night time comfort Press any key to restore maximum brightness The 5 LEDs display the operational states Mi...

Страница 19: ...y Operation Display Each time the mode off button is pressed the fan speed moves between supersilent minimum medium and maximum The function being activated is indicated by the relevant symbol appeari...

Страница 20: ...e painted surfaces When necessary clean the outer surfaces of the heat pump convector with a soft damp cloth Cleaning air suction filter To remove the grill lift the grill until it is completely relea...

Страница 21: ...g detergents or solvents and leave to dry It is forbidden to use the unit without the net filters The appliance is fitted with a safety switch that prevents the operation of the cooler with the mobile...

Страница 22: ...s into the special slots turn it and hook it up with a slight tap on the upper part Ending Cleaning Operations Energy saving tips Always keep the filters clean when far possible keep the doors and win...

Страница 23: ...an can turn freely The microswitch that stops ventilation when opening the filter grill doesn t close properly Check that closing the grill closes the contact on the microswitch Electrical connections...

Страница 24: ...Copyright 2019 Daikin...