background image

19

S

U I

5.4 

5.5 

5.6 

5.7 

5.8 

5.9 

Activation

Stand By

To activate the device

Key

Operation

Display

Press the mode/off key

Off 

 On

Select one of the 4 operating speeds by pressing the relative mode/off key. If the red

symbol 

 is flashing, it means that the room thermostat is not connected; it therefore 

needs to be activated.

Key

Operation

Display

Press and hold the mode/off key for approx. 2 seconds. No illuminated signals on the 
display at all means that the system is in stand-by (no operation).

Off 

 On

Ventilation speed regulation 

By setting the highest speed, the maximum possible 
power level is activated immediately whether heating or 
cooling.

Once the desired room temperature is reached, we 
recommend selecting one of the other 3 operation modes 
for increased comfort and sound levels.

Key

Operation

Display

Each time the mode/off button is pressed the fan speed moves between supersilent, 
minimum, medium and maximum.
The function being activated is indicated by the relevant symbol appearing on the 
display.

Deactivation

Switching off for long periods

When switching off for a season or for holidays, proceed 
as follows:

-  Deactivate the device
-  Turn the general unit switch to off.

Key

Operation

Display

Press and hold the mode/off key for approx. 2 seconds. No illuminated signals on the 
display at all means that the system is in stand-by (no operation).

Off

Error status warnings

The board provides diagnostics in the event of anomalies, 
which can be interpreted from combinations of LEDs.
The following table summarises the warnings.

• 

Flashing LED 

: TERM contact open

• 

Flashing LED 

: TERM contact closed;

• 

4 flashing LEDs: GRID contact open;

• 

 LED on: supersilent speed active (400 rpm).

• 

 LED on: minimum speed active (680 rpm).

• 

 LED on: medium speed active (1,100 rpm).

• 

 LED on: maximum speed active (1,500 rpm).

Содержание Altherma EKRTCTRL2

Страница 1: ...EKRTCTRL1 EKRTCTRL2 EKWHCTRL0 EKWHCTRL1 EKPCBO USER MANUAL Daikin Altherma heat pump convector options...

Страница 2: ...use of the appliance in a rapid unmistakable way Symbols U User Refers to pages containing instructions or information for the user I Installer Refers to pages containing instructions or information...

Страница 3: ...8 2 15 Deactivation 9 2 16 Room temperature probe regulation offset 9 2 17 Switching off for long periods 9 2 18 Error signals 9 3 EKWHCTRL1 3 1 Wall mounted SMART TOUCH electronic control panel with...

Страница 4: ...3 Room temperature probe regulation offset 17 4 14 Switching off for long periods 17 4 15 Error signals 17 5 EKPCBO 5 1 On board speed selector for connecting to standard thermostat 18 5 2 LED indicat...

Страница 5: ...roduct that uses electricity and water such as The unit can be used by children over the age of 8 and by people with reduced physical sensory or mental capabilities or with no experience or necessary...

Страница 6: ...s functions are set using 8 backlit keys Any statuses and alarms are also shown on the display by using 8 specific symbols EKRTCTRL1 Automatic operation Silent operation Maximum ventilation speed Nigh...

Страница 7: ...hese values for brief periods and then set a intermediate value The controller is very precise set it to the required value and wait for the controller to regulate itself according to the actual room...

Страница 8: ...whenever any key is pressed LOC will appear To unlock the keys repeat the sequence Key Operation Display Press and hold the Max Operation key The function being activated is indicated by the relevant...

Страница 9: ...ment using the and keys of the AIR probe offset displayed from 9 to 12 K in 0 1 K intervals After 20 seconds from the last action the panel switches off and the setting is stored The controller also e...

Страница 10: ...also shown on the display by using 8 specific symbols Automatic operation Silent operation Maximum ventilation speed Night time operation Heating on Cooling on Supervision on Flashing with presence s...

Страница 11: ...To activate the device Key Operation Display Keep the Heating Cooling key pressed for approx 2 seconds to change the mode between heating and cooling which is indicated by the 2 symbols that appear if...

Страница 12: ...his is indicated by bL appearing on the display All actions are disabled to the user and whenever any key is pressed LOC will appear To unlock the keys repeat the sequence Key Operation Display Press...

Страница 13: ...vice Key Operation Display With the display off press and hold the key for 5 seconds to access the menu which allows adjustment using the and keys of the AIR probe offset displayed from 9 to 12 K in 0...

Страница 14: ...ng 8 backlit keys Any statuses and alarms are also shown on the display by using 8 specific symbols EKRTCTRL2 Automatic operation in steps Minimum operation Maximum ventilation speed Super silent oper...

Страница 15: ...pened The adjustment range is from 16 to 28 C in intervals of 1 C but out of range values are also accepted from 5 C to 40 C unless in auto mode Only set these values for brief periods and then set a...

Страница 16: ...vated immediately whether heating or cooling Once the desired room temperature is reached we recommend selecting one of the other 3 operation modes for increased comfort and sound levels In minimum mo...

Страница 17: ...stment with care and only after having actually detected a discrepancy compared with the actual room temperature using a reliable device Key Operation Display With the display off press and hold the k...

Страница 18: ...series After 20 seconds from the last action the LED brightness will be reduced for improved night time comfort Press any key to restore maximum brightness The 5 LEDs display the operational states Mi...

Страница 19: ...y Operation Display Each time the mode off button is pressed the fan speed moves between supersilent minimum medium and maximum The function being activated is indicated by the relevant symbol appeari...

Страница 20: ...e painted surfaces When necessary clean the outer surfaces of the heat pump convector with a soft damp cloth Cleaning air suction filter To remove the grill lift the grill until it is completely relea...

Страница 21: ...g detergents or solvents and leave to dry It is forbidden to use the unit without the net filters The appliance is fitted with a safety switch that prevents the operation of the cooler with the mobile...

Страница 22: ...s into the special slots turn it and hook it up with a slight tap on the upper part Ending Cleaning Operations Energy saving tips Always keep the filters clean when far possible keep the doors and win...

Страница 23: ...an can turn freely The microswitch that stops ventilation when opening the filter grill doesn t close properly Check that closing the grill closes the contact on the microswitch Electrical connections...

Страница 24: ...Copyright 2019 Daikin...

Отзывы: