Daikin Altherma EKHWE150A3V3 Скачать руководство пользователя страница 3

 

EKHWE150~3 E300A3Z2

 

Domestic hot water tank for air to water heat pump system

 

4PW43396-1D

 

Installation manual

 

1

 

C

 

ONTENTS

 

Page

 

Introduction........................................................................................ 1

 

General information ................................................................................... 1
Scope of this manual ................................................................................. 1
Model identification .................................................................................... 1

 

Accessories ....................................................................................... 1

 

Accessories supplied with the domestic hot water tank............................. 1

 

Warranty ............................................................................................ 1

Installation of the EKHWE domestic hot water tank .......................... 2

 

Main components....................................................................................... 2
Outlook diagram......................................................................................... 3
Installation guidelines................................................................................. 3
Installing the domestic hot water tank........................................................ 3
Connecting the water circuits ..................................................................... 3
Field wiring................................................................................................. 4

 

Commissioning .................................................................................. 6

Maintenance ...................................................................................... 6

Troubleshooting ................................................................................. 7

 

General guidelines ..................................................................................... 7
General symptoms..................................................................................... 7

 

Technical specifications ..................................................................... 7

 

Domestic hot water tank specifications ...................................................... 7

 

I

 

NTRODUCTION

 

General information

 

Thank you for purchasing this domestic hot water tank.

The EKHWE domestic hot water tank with integrated 3 kW electrical
booster heater must be connected to the indoor unit. The domestic
hot water tank is available in three sizes: 150, 200 and 300 litre. All
models are floor mounted, while the 150 litre model
EKHWET150A3V3 is wall mounted. The 200 and 300 litre models
are also available as 400 V versions.

 

Scope of this manual

 

This installation manual describes the procedures for unpacking,
installing and connecting the EKHWE domestic hot water tanks.

 

Model identification

 

A

 

CCESSORIES

 

Accessories supplied with the domestic hot water tank

 

See 

figure 1

 

W

 

ARRANTY

 

EKHWE150A3V3

EKHWET150A3V3

EKHWE200A3V3

EKHWE200A3Z2

EKHWE300A3V3

EKHWE300A3Z2

 

Domestic hot water tank 

for air to water heat pump system

 

Installation manual

 

READ THESE INSTRUCTIONS CAREFULLY BEFORE
INSTALLATION. KEEP THIS MANUAL IN A HANDY
PLACE FOR FUTURE REFERENCE.

IMPROPER INSTALLATION OR ATTACHMENT OF
EQUIPMENT OR ACCESSORIES COULD RESULT IN
ELECTRIC SHOCK, SHORT-CIRCUIT, LEAKS, FIRE OR
OTHER DAMAGE TO THE EQUIPMENT. BE SURE ONLY
TO USE ACCESSORIES MADE BY DAIKIN WHICH ARE
SPECIFICALLY DESIGNED FOR USE WITH THE
EQUIPMENT AND HAVE THEM INSTALLED BY A
PROFESSIONAL.

IF UNSURE OF INSTALLATION PROCEDURES OR USE,
ALWAYS CONTACT YOUR DAIKIN DEALER FOR
ADVICE AND INFORMATION.

THE UNIT DESCRIBED IN THIS MANUAL IS DESIGNED
FOR INDOOR INSTALLATION ONLY AND FOR AMBIENT
TEMPERATURES RANGING 0°C~35°C.

 

EK

HWE

(T)

150

A

3

V3

 

Booster heater voltage
V3 = 1P, 230 V
Z2 = 2P, 400 V (only for 
200 l and 300 l models)

Capacity booster heater: 3 kW

Series

Indication of storage capacity in litres

T = wall mounted; otherwise, floor standing

Hot Water tank Enamel coated

European Kit

 

1

 

Ther connection wire (12 m)

 

2

 

Contactor - fuse assembly

 

3

 

Contactor fixing screw

 

4

 

Tapping screw

 

5

 

Installation manual

 

6

 

3-way valve (Rp 1")

 

7

 

3-way valve motor

 

Warranty will not be valid if

 

 

a pressure relief valve of max. 10 bar is not installed.

 

 

abnormal corrosion occurred due to not installing
dielectric couplings.

 

 

incorrect electric connections are made.

 

 

applying electric power to the unit before filling it with
water.

 

 

insufficient maintenance, in particular not inspecting
the anode every 2 years and replacing if required.

Содержание Altherma EKHWE150A3V3

Страница 1: ...INSTALLATION MANUAL EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3 EKHWE200A3Z2 EKHWE300A3Z2 Domestic hot water tank for air to water heat pump system ...

Страница 2: ... 30 30 50 700 300 440 500 4 5 30 30 700 400 705 220 255 280 35 115 775 1150 13 21 355 440 50 EKHWE150 300 EKHWET150 D1 1150 775 280 255 35 545 1525 925 280 410 35 545 1525 851 210 410 27 660 H1 H2 H3 H4 H5 Ø D1 150 200 EKHWE 300 A A A A 16 16 16 400 400 0 400 77 111 38 67 44 2 1 3 ...

Страница 3: ... EKHWET150A3V3 EKHWE200A3V3 EKHWE200A3Z2 EKHWE300A3V3 EKHWE300A3Z2 Domestic hot water tank for air to water heat pump system Installation manual READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK SHORT CIRCUIT LEAKS FIRE OR OTHER DAMAGE TO THE EQU...

Страница 4: ...stic hot water quality must be according to EN directive 98 83 EC A drain device should be installed on the cold water connection on the domestic hot water tank For safety reasons it is not allowed to add ethylene glycol to the water circuit Adding ethylene glycol might lead to contamination of the domestic water if a leakage would occur in the heat exchanger coil It is important that the storage ...

Страница 5: ...d back siphonage it is advised to install a non return valve on the water inlet of the domestic hot water tank in accordance with local and national regulations Installing the domestic hot water tank 1 Check if all domestic hot water tank accessories see Accessories on page 1 are enclosed 2 When floor mounting place the domestic hot water tank on a level surface If required adjust the legs at the ...

Страница 6: ...tions refer to Field wiring in the indoor unit installation manual supplied with the EKHBH X unit Installation in accordance with figure A and figure B Installation in accordance with figure C and figure D If the valve is not positioned in this way before mounting the motor the valve will give way to both domestic water and room heating during operation Installation in accordance with figure A and...

Страница 7: ...ector connected to the contactor K3M in the socket X13A on the PCB 5 Plug the thermistor cable connector in the socket X9A on the PCB 6 Connect the prewired earth wires of the terminal block X3M and X4M to the earthing screw 7 Connect the booster heater power supply and thermal protection cable field supply to terminal X4M earth 1 2 and X2M 13 14 8 Connect the booster heater power supply cable to ...

Страница 8: ...le the booster heater and the heat exchanger 3 Once every 2 year Anode Check if the anode is not deteriorated If the diameter of the anode has decreased with 10 mm or more make sure to replace it original diameter is 33 mm A4P K6M F2B K3M K7M 2 1 X4M 4a OPTIONAL X2M 21 20 Q2L 3 wayvalve 2 wayvalve 12 11 4 thermostat 2 1 3 5 6 7 8 9 10 13 19 thermal fuse 14 15 16 17 18 SOLARPUMP N L L2 L1 X3M 230V ...

Страница 9: ...in water supply is off Check that all shut off valves of the water circuit are completely open POSSIBLE CAUSES CORRECTIVE ACTION The thermal cut out s has have operated Check and reset button s Put the thermostat setting for domestic hot water on the indoor unit to 75 C Check if thermistor is correctly installed in thermistor socket The indoor unit EKHBH X is not operating Check the indoor unit EK...

Страница 10: ...4PW43396 1D Copyright Daikin ...

Отзывы: