Installation manual

6

EKHWE150~3 E300A3Z2

Domestic hot water tank for air to water heat pump system

4PW43396-1D

Note: only relevant field wiring is shown.

C

OMMISSIONING

Before putting power to the unit, make sure:

the unit is filled with water,

the sensor of the thermistor cable is mounted correctly in the
thermistor socket,

a pressure relief valve is installed.

Check the operation of the 3-way valve: make sure that when the
indoor unit is in domestic water mode it sends hot water to the tank;
when it is in room heating mode, it sends water to the room (feel the
tubes by hand).

M

AINTENANCE

In order to ensure optimal availability of the unit, a number of checks
and inspections on the unit and the field wiring have to be carried out
at regular intervals.

1

The pressure relief device valve is to be operated regularly as to
remove lime deposits and to verify that it is not blocked.

2

Once a year: Descaling

Depending on the water and set temperature, scale will deposit
on the heat exchanger and booster heater inside the domestic
hot water tank.

This will restrict heat transfer and can cause burn out of the
booster heater. For this reason, descale the booster heater and
the heat exchanger.

3

Once every 2 year: Anode.

Check if the anode is not deteriorated. If the diameter of the
anode has decreased with 10 mm or more, make sure to
replace it (original diameter is 33 mm).

A4P

K6M

F2B

K3M

K7M

2

1

X4M

4a

OPTIONAL

X2M

21

20

Q2L

3-way valve

2-way valve

12

11

4

thermostat

2

1

3

5

6

7

8

9

10

13

19

thermal
 fuse

14

15

16

17

18

SOLAR PUMP

N

L

L2

L1

X3M (230V)

F1B

TR1

TR1

A1P

A1P

X2M

X1M

K5M

K2M

K1M

K1M

K2M

K5M

K4M

1

2

3

L1

L2

L3

N

15a

K3M

X9A

X13A

1 2

4

2

3

X4M

X2M

>50 mm

3 way

valve

L

BRN

BLU

BLK

N Y

X4M

X3M

230 V AC

3 kW

L N

400 V AC

3 kW

L1 L2

V3

Z2

Before carrying out any maintenance or repair activity,
always switch off the circuit breaker on the supply
panel, remove the fuses or open the protection
devices of the unit.

Make sure that before starting any maintenance or
repair activity, also the power supply to the outdoor
unit is switched off.

Do not use sharp metal tools or strong acid to remove the
scaling. Only use commercially available cleaning and
scale removal agents for copper and enamelled surfaces.

After removing the scale, rinse the domestic hot water tank
by water jet.

It is of the utmost importance that the anode is in good
contact with the domestic hot water tank. For this reason,
after replacing the anode or other servicing, make sure
that the anode is connected with the earthing screw.

Содержание Altherma EKHWE150A3V3

Страница 1: ...INSTALLATION MANUAL EKHWE150A3V3 EKHWET150A3V3 EKHWE200A3V3 EKHWE300A3V3 EKHWE200A3Z2 EKHWE300A3Z2 Domestic hot water tank for air to water heat pump system ...

Страница 2: ... 30 30 50 700 300 440 500 4 5 30 30 700 400 705 220 255 280 35 115 775 1150 13 21 355 440 50 EKHWE150 300 EKHWET150 D1 1150 775 280 255 35 545 1525 925 280 410 35 545 1525 851 210 410 27 660 H1 H2 H3 H4 H5 Ø D1 150 200 EKHWE 300 A A A A 16 16 16 400 400 0 400 77 111 38 67 44 2 1 3 ...

Страница 3: ... EKHWET150A3V3 EKHWE200A3V3 EKHWE200A3Z2 EKHWE300A3V3 EKHWE300A3Z2 Domestic hot water tank for air to water heat pump system Installation manual READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION KEEP THIS MANUAL IN A HANDY PLACE FOR FUTURE REFERENCE IMPROPER INSTALLATION OR ATTACHMENT OF EQUIPMENT OR ACCESSORIES COULD RESULT IN ELECTRIC SHOCK SHORT CIRCUIT LEAKS FIRE OR OTHER DAMAGE TO THE EQU...

Страница 4: ...stic hot water quality must be according to EN directive 98 83 EC A drain device should be installed on the cold water connection on the domestic hot water tank For safety reasons it is not allowed to add ethylene glycol to the water circuit Adding ethylene glycol might lead to contamination of the domestic water if a leakage would occur in the heat exchanger coil It is important that the storage ...

Страница 5: ...d back siphonage it is advised to install a non return valve on the water inlet of the domestic hot water tank in accordance with local and national regulations Installing the domestic hot water tank 1 Check if all domestic hot water tank accessories see Accessories on page 1 are enclosed 2 When floor mounting place the domestic hot water tank on a level surface If required adjust the legs at the ...

Страница 6: ...tions refer to Field wiring in the indoor unit installation manual supplied with the EKHBH X unit Installation in accordance with figure A and figure B Installation in accordance with figure C and figure D If the valve is not positioned in this way before mounting the motor the valve will give way to both domestic water and room heating during operation Installation in accordance with figure A and...

Страница 7: ...ector connected to the contactor K3M in the socket X13A on the PCB 5 Plug the thermistor cable connector in the socket X9A on the PCB 6 Connect the prewired earth wires of the terminal block X3M and X4M to the earthing screw 7 Connect the booster heater power supply and thermal protection cable field supply to terminal X4M earth 1 2 and X2M 13 14 8 Connect the booster heater power supply cable to ...

Страница 8: ...le the booster heater and the heat exchanger 3 Once every 2 year Anode Check if the anode is not deteriorated If the diameter of the anode has decreased with 10 mm or more make sure to replace it original diameter is 33 mm A4P K6M F2B K3M K7M 2 1 X4M 4a OPTIONAL X2M 21 20 Q2L 3 wayvalve 2 wayvalve 12 11 4 thermostat 2 1 3 5 6 7 8 9 10 13 19 thermal fuse 14 15 16 17 18 SOLARPUMP N L L2 L1 X3M 230V ...

Страница 9: ...in water supply is off Check that all shut off valves of the water circuit are completely open POSSIBLE CAUSES CORRECTIVE ACTION The thermal cut out s has have operated Check and reset button s Put the thermostat setting for domestic hot water on the indoor unit to 75 C Check if thermistor is correctly installed in thermistor socket The indoor unit EKHBH X is not operating Check the indoor unit EK...

Страница 10: ...4PW43396 1D Copyright Daikin ...