![Daikin Altherma EKHWE150A3V3 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/daikin/altherma-ekhwe150a3v3/altherma-ekhwe150a3v3_installation-manual_3298335009.webp)
EKHWE150~3 E300A3Z2
Domestic hot water tank for air to water heat pump system
4PW43396-1D
Installation manual
7
T
ROUBLESHOOTING
This section provides useful information for diagnosing and correct-
ing certain troubles which may occur in the unit.
General guidelines
Before starting the troubleshooting procedure, carry out a thorough
visual inspection of the unit and look for obvious defects such as
loose connections or defective wiring.
Before contacting your local dealer, read this chapter carefully, it will
save you time and money.
When a safety device was activated, stop the unit and find out why
the safety device was activated before resetting it. Under no circum-
stances safety devices may be bridged or changed to a value other
than the factory setting. If the cause of the problem cannot be found,
call your local dealer
General symptoms
Symptom 1: No water flow from hot taps
Symptom 2: Water from hot taps is cold
T
ECHNICAL
SPECIFICATIONS
Domestic hot water tank specifications
When carrying out an inspection on the supply panel or on
the switch box of the unit, always make sure that the circuit
breaker of the unit is switched off.
P
OSSIBLE
CAUSES
C
ORRECTIVE
ACTION
The main water supply is off.
Check that all shut off valves of the
water circuit are completely open.
P
OSSIBLE
CAUSES
C
ORRECTIVE
ACTION
The thermal cut-out(s) has/have
operated
• Check and reset button(s).
• Put the thermostat setting for
domestic hot water on the indoor unit
to
≤
75°C.
• Check if thermistor is correctly
installed in thermistor socket.
The indoor unit (EKHBH/X) is not
operating.
Check the indoor unit (EKHBH/X)
operation. Refer to the manual
delivered with the indoor unit.
If any faults are suspected, contact
your local dealer.
EKHWE150A3V3
EKHWET150A3V3
EKHWE200A3V3
EKHWE200A3Z2
EKHWE300A3V3
EKHWE300A3Z2
Volume
150 l
150 l
200 l
200 l
300 l
300 l
Internal heat exchanger volume
2 l
2 l
3 l
3 l
3 l
3 l
Overall dimensions (Ø x H)
545 x 1150 mm
545 x 1150 mm
545 x 1525 mm
545 x 1525 mm
660 x 1525 mm
660 x 1525 mm
Booster heater, power supply
230 V 50 Hz 1P
230 V 50 Hz 1P
230 V 50 Hz 1P
400 V 50 Hz 2P
230 V 50 Hz 1P
400 V 50 Hz 2P
Booster heater, running current
13 A
13 A
13 A
7.5 A
13 A
7.5 A
Booster heater, capacity
3 kW
3 kW
3 kW
3 kW
3 kW
3 kW
Connections
Refer to
Weight (empty)
80 kg
82 kg
104 kg
104 kg
140 kg
140 kg
Mounting
Floor
Wall
Floor
Floor
Floor
Floor
Maximum pressure
10 bar
10 bar
10 bar
10 bar
10 bar
10 bar
Maximum domestic hot water
temperature
75°C
75°C
75°C
75°C
75°C
75°C
Maximum temperature through
heat exchanger
110°C
110°C
110°C
110°C
110°C
110°C
Содержание Altherma EKHWE150A3V3