Specifications
ESIE06-03
1–16
3
11
4
5
2.2
ERYQ005~007
Technical
specifications
The table below contains the technical specifications.
Specification
ERYQ005~007
Casing
Colour
Ivory white
Material
Polyester painted galvanised steel
Dimensions
Packing
Height
797 mm
Width
960 mm
Depth
390 mm
Unit Height
735
mm
Width
825 mm
Depth
300 mm
Weight
Machine weight
56 kg
Gross weight
61 kg
Packing
Material
EPS, CARTON
Weight
5 kg
Heat exchanger
Specifications
Length
845 mm
Nr. of rows
2
Fin pitch
1.8 mm
Nr. of passes
—
Face area
—
Nr. of stages
32 m²
Tube type
Hi-Xa(8)
Fin Type
WF
fin
Treatment
Anti-corrosion treatment (PE)
Fan
Type
Propeller
Discharge direction
Horizontal
Quantity
1
Air flow rate (nominal at 230 V)
Heating high
—
Heating low
—
Cooling high
—
Cooling low
—
Motor Quantity
1
Output
53 W
Compressor
Quantity
1
Motor Model
2YC63BXD#C
Type
Hermetically sealed swing compressor
Output
1920 W
Operation range (see Altherma
operation manual)
Heating Min.
-20°C
DB
Max.
25°C DB
Cooling
Min.
7°C WB
Max.
20°C WB
Sanitary water
Min.
-20°C DB
Max.
43°C DB
Sound level (nominal)
Heating
Sound power (5/6/7)
64/64/66 dBA
Sound pressure (5/6/7)
48/48/52 dBA
Cooling
Sound power
63/64/66 dBA
Sound pressure (5/6/7)
47/47/53 dBA
Sound level (night quiet)
Sound pressure
—
Refrigerant
Type
R410A
Charge
1.7 kg
Control
Expansion valve (electronic type)
Nr. of circuits
1
Содержание Altherma EKHBH Series
Страница 2: ...ESIE06 03 1 2 Part 1 System Outline 3 1 1 5 ...
Страница 26: ...Functional Diagrams ESIE06 03 1 26 Part 1 System Outline 3 1 1 4 5 ...
Страница 32: ...Piping Diagrams ESIE06 03 1 32 Part 1 System Outline 3 1 1 4 5 ...
Страница 38: ...Switch Box Layout ESIE06 03 1 38 Part 1 System Outline 3 1 1 4 5 ...
Страница 58: ...PCB Layout ESIE06 03 1 58 Part 1 System Outline 3 1 1 4 5 ...
Страница 60: ...ESIE06 03 2 2 Part 2 Functional Description 3 1 2 5 ...
Страница 68: ...Hydro box Functional Concept ESIE06 03 2 10 Part 2 Functional Description 3 1 2 4 5 ...
Страница 88: ...ESIE06 03 3 2 Part 3 Troubleshooting 3 1 3 5 ...
Страница 134: ...Error Codes System Malfunctions ESIE06 03 3 48 Part 3 Troubleshooting 3 1 3 4 5 ...
Страница 152: ...Additional Checks for Troubleshooting ESIE06 03 3 66 Part 3 Troubleshooting 3 1 3 4 5 ...
Страница 154: ...ESIE06 03 5 2 Part 5 Disassembly and Maintenance 3 1 5 ...
Страница 180: ...Removal procedure outdoor unit ERYQ005 007AAV3 ESIE06 03 5 28 Part 5 Disassembly and Maintenance 3 1 5 5 ...