Electrical installation
Installer reference guide
94
ERGA04~08EAV3(A) + 08S18+9W
Daikin Altherma 3 R F
4P629093-1 – 2020.08
a
Strip wire end to this point
b
An excessive strip length may cause electrical shock or leakage
4
Connect the interconnection cable and power supply as follows. Ensure stress
relief by using the wire clamp.
a
c
d
1N~ 50 Hz
220-240 V
b
a
Interconnection cable
b
Power supply cable
c
Fuse
d
Earth leakage circuit breaker
1 2 3
L
N
L N PWR
12 3
3×
a
a
Wire clamp
5
Reattach the switch box cover.
6
Reattach the refrigerant piping cover. Make sure the cables are routed under
the cover as shown:
7
Connect an earth leakage circuit breaker and fuse to the power supply line.