background image

2

 | 

User safety instructions

User reference guide

8

EBSH/X(B)11+16P30+50DF

Daikin Altherma 3 R ECH₂O

4P663484-1 – 2021.07

Units are marked with the following symbol:

This  means  that  electrical  and  electronic  products  may  NOT  be  mixed  with
unsorted  household  waste.  Do  NOT  try  to  dismantle  the  system  yourself:  the
dismantling of the system, treatment of the refrigerant, of oil and of other parts
MUST  be  done  by  an  authorised  installer  and  MUST  comply  with  applicable
legislation.

Units MUST be treated at a specialised treatment facility for reuse, recycling and
recovery.  By  ensuring  this  product  is  disposed  of  correctly,  you  will  help  to
prevent  potential  negative  consequences  for  the  environment  and  human
health. For more information, contact your installer or local authority.

Batteries are marked with the following symbol:

This  means  that  the  batteries  may  NOT  be  mixed  with  unsorted  household
waste. If a chemical symbol is printed beneath the symbol, this chemical symbol
means that the battery contains a heavy metal above a certain concentration.

Possible chemical symbols are: Pb: lead (>0.004%).

Waste batteries MUST be treated at a specialised treatment facility for reuse. By
ensuring  waste  batteries  are  disposed  of  correctly,  you  will  help  to  prevent
potential negative consequences for the environment and human health.

2.2 Instructions for safe operation

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

WARNING

The appliance shall be stored so as to prevent mechanical
damage  and  in  a  well-ventilated  room  without
continuously  operating  ignition  sources  (example:  open
flames, an operating gas appliance or an operating electric
heater).

WARNING

Do NOT pierce or burn refrigerant cycle parts.

Do  NOT  use  cleaning  materials  or  means  to  accelerate
the  defrosting  process  other  than  those  recommended
by the manufacturer.

Be  aware  that  the  refrigerant  inside  the  system  is
odourless.

Содержание Altherma 3 R ECH2O

Страница 1: ...ikin Altherma 3 R ECH O EBSH11P30DF EBSHB11P30DF EBSH11P50DF EBSHB11P50DF EBSH16P30DF EBSHB16P30DF EBSH16P50DF EBSHB16P50DF EBSX11P30DF EBSXB11P30DF EBSX11P50DF EBSXB11P50DF EBSX16P30DF EBSXB16P30DF E...

Страница 2: ...om temperature 28 5 6 5 To change the desired leaving water temperature 29 5 7 Domestic hot water control 30 5 7 1 About domestic hot water control 30 5 7 2 Reheat mode 31 5 7 3 Scheduled reheat mode...

Страница 3: ...B 11 16P30 50DF Daikin Altherma 3 R ECH O 4P663484 1 2021 07 9 Relocation 60 9 1 Overview Relocation 60 10 Disposal 61 11 Glossary 62 12 Installer settings Tables to be filled in by installer 63 12 1...

Страница 4: ...of the indoor unit User reference guide Detailed step by step instructions and background information for basic and advanced usage Format Digital files on http www daikineurope com support and manuals...

Страница 5: ...u screen press the help button The breadcrumbs appear in the top left corner of the screen 2 To disable the breadcrumbs Press the help button again This document also mentions these breadcrumbs Exampl...

Страница 6: ...ituation that could result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Explanation Before installation read the installa...

Страница 7: ...physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards...

Страница 8: ...OT be mixed with unsorted household waste If a chemical symbol is printed beneath the symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible c...

Страница 9: ...ate the room and contact the dealer where you purchased the unit Do NOT use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired WARNING Air purgi...

Страница 10: ...TION If underfloor heating is installed in the main zone then in cooling mode the main zone can only provide refreshment Real cooling is then NOT allowed 3 1 Components in a typical system layout g A...

Страница 11: ...through the list of digits and change the selected digit Move the cursor from left to right Confirm the pin code and proceed User pin code The User pin code is 0000 0000 User Advanced user pin code T...

Страница 12: ...rature control you can use the room temperature setpoint screen to read out and adjust the desired room temperature 1 Go to 1 Room Room 1 2 Adjust the desired room temperature 21 C 1 a b Room a Actual...

Страница 13: ...e Additional zone Cooling 3 6 Additional zone Cooling WD curve 2 Change the weather dependent curve There are 2 types of WD curves slope offset curve default and 2 points curve If needed you can chang...

Страница 14: ...he temperature Go to the next temperature Confirm changes and proceed More information For more information see also 5 4 Turning operation ON or OFF 424 5 6 Space heating cooling control 426 5 8 Prese...

Страница 15: ...resulting domestic hot water temperature depends on this setpoint as well as the actual storage tank temperature 1 Go to 5 Tank Tank 5 2 Adjust the domestic hot water temperature 50 C 5 a b Tank a Act...

Страница 16: ...ion Slot for WLAN cartridge With the WLAN cartridge the installer can connect the system to the internet As user you can then control the system via the Daikin Residential Controller app Note This slo...

Страница 17: ...Turn the left dial Choose a menu item Press the left dial Confirm your choice or go to a submenu b Back button Press to go back 1 step in the menu structure c Home button Press to go back to the home...

Страница 18: ...Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet Activation Schedule Level 7 5 Electricity price High Medium Low Schedule 5 Tank Powerful operation Schedule 1 9 Room comfort se...

Страница 19: ...with weather dependent curve c4 Screen with schedule 5 3 1 Home screen Press the button to go back to the home screen You see an overview of the unit configuration and the room and setpoint temperatu...

Страница 20: ...at pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currently being used for space heating e3 Smart energy is cu...

Страница 21: ...erfloor heating Fancoil unit Radiator i3 21 Measured room temperature a i4 35 Leaving water temperature setpoint a j Holiday mode Holiday mode active k Additional zone k1 Installed room thermostat typ...

Страница 22: ...Human Comfort Interface BRC1HHDA used as room thermostat is controlling the indoor unit Set the room temperature 2 Main zone Shows the applicable symbol for your main zone emitter type Set the leaving...

Страница 23: ...ikin Residential Controller app 5 3 3 Setpoint screen The setpoint screen is displayed for screens describing system components that need a setpoint value Examples 1 Room temperature screen 21 C 1 Roo...

Страница 24: ...1 30 Minutes a Settings b Values c Selected setting and value Possible actions on this screen Go through the list of settings Change the value Go to the next setting Confirm changes and proceed 5 4 Tu...

Страница 25: ...for leaving water temperature control and external room thermostat control the protection is NOT guaranteed 1 Go to C 2 Operation Space heating cooling Operation Space heating cooling Tank Off On C 2...

Страница 26: ...6 Operation modes Current operation mode Example Defrost oil return mode 8 7 About Version information about the system 8 8 Connection status Information about the connection status of the unit the ro...

Страница 27: ...to a monthly schedule To check which space operation mode is currently used The space operation mode is displayed on the home screen When the unit is in heating mode the icon is shown When the unit is...

Страница 28: ...filled in by the installer To determine which temperature control you are using method 2 You can see on the home screen which temperature control you are using 6 1 6 bar 22 19 55 21 35 45 a2 a1 b 18 F...

Страница 29: ...ction occurs You can avoid scheduled behaviour by temporarily turning off scheduling To turn off room temperature scheduling 1 Go to 1 1 Room Schedule 2 Select No 5 6 5 To change the desired leaving w...

Страница 30: ...aving water temperature scheduling 1 Go to one of the following 2 1 Main zone Schedule 3 1 Additional zone Schedule 2 Select No To enable weather dependent operation for the leaving water temperature...

Страница 31: ...eat only 5 1 Powerful operation and 5 5 Schedule are displayed Scheduled reheat 5 7 2 Reheat mode In reheat mode the storage tank continuously heats up to the temperature shown on the home screen exam...

Страница 32: ...ank is heated up to 50 C During the afternoon and evening you consume hot water again and the DHW tank temperature decreases again When the tank temperature drops below a preset value set temperature...

Страница 33: ...water tank will start heating up the water to the Comfort temperature INFORMATION When powerful operation is active the risk of space heating cooling and capacity shortage comfort problems is signifi...

Страница 34: ...ntly want to use for a specific control The system contains some predefined schedules You can Consult which schedule is currently selected Schedule Control in Possible schedules 434 Select another sch...

Страница 35: ...es 3 Activation screen 1 1 Schedule Possible actions Temperatures within range 1 3 Room Cooling schedule Schedule for the desired room temperature in cooling mode Predefined schedules 1 Activation scr...

Страница 36: ...ater needs Predefined schedules 1 Activation screen Not applicable This schedule is automatically activated if the DHW mode is the following Scheduled reheat 7 4 2 User settings Quiet Schedule Schedul...

Страница 37: ...he whole week schedule or the content of a selected day schedule 3 Program the schedule for Monday 4 Copy the schedule to the other weekdays 5 Program the schedule for Saturday and copy it to Sunday 6...

Страница 38: ...actions each day On the bar a high temperature has a darker colour than a low temperature 0 6 00 8 30 17 30 20 C 18 C 22 00 18 C 21 C 12 24 Mon Note To clear an action set its time as the time of the...

Страница 39: ...lect Paste Delete Edit Copy Paste Result Mon Sat Wed Fri Thu Tue Sun User defined 1 C 5 Repeat this action for all other weekdays Mon Sat Wed Fri Thu Tue Sun User defined 1 C To program the schedule f...

Страница 40: ...me the current schedule browse through the character list and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the new name INFORMATION Not all schedules can...

Страница 41: ...NFORMATION If no schedule is set the Electricity price for High is taken into account To set the electricity price schedule timer 1 Go to 7 5 4 User settings Electricity price Schedule 2 Program the s...

Страница 42: ...h 5 Calculation of the gas price Gas price Actual gas price Incentive kWh 0 9 Gas price 4 08 5 0 9 Gas price 8 58 Calculation of the electricity price Electricity price Actual electricity price Incent...

Страница 43: ...usted by an installer or user Types of weather dependent curve There are 2 types of weather dependent curves 2 points curve Slope offset curve Which type of curve you use to make adjustments depends o...

Страница 44: ...efine the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving water for different ambient temperatures For example if le...

Страница 45: ...one heating Main zone or additional zone cooling Domestic hot water X1 X2 Examples of outdoor ambient temperature Y1 Y2 Y3 Y4 Examples of desired tank temperature or leaving water temperature The icon...

Страница 46: ...e type for all zones main additional and for the tank go to 2 E Main zone WD curve type Viewing which type is selected is also possible via 3 C Additional zone WD curve type 5 E Tank WD curve type Res...

Страница 47: ...mperatures Slope Offset OK Cold OK Hot Cold OK Cold Cold Cold Hot Hot OK Hot Cold Hot Hot To fine tune the weather dependent curve 2 points curve The following table describes how to fine tune the wea...

Страница 48: ...ble if enabled by the installer 1 Go to 7 4 2 User settings Quiet Schedule 2 Program the schedule Possible actions You can use the following system defined preset values Quiet More quiet Most quiet Fo...

Страница 49: ...of your holiday Go to 7 3 3 Till Select a date Confirm the changes 5 10 4 Using WLAN INFORMATION Restriction WLAN settings are only visible when a WLAN module is installed About the WLAN module The w...

Страница 50: ...LAN module active as access point 1 Go to D 1 Wireless gateway Mode 2 In the Enable AP mode screen select Yes D 2 WPS Connect the WLAN module to the router 1 Go to D 2 Wireless gateway WPS 2 In the Co...

Страница 51: ...ay Malfunctioning Operation User profile Room D Wireless gateway D 1 Mode D 2 Reboot D 3 WPS D 4 Remove from cloud D 5 Home network connection D 6 Cloud connection D 1 Mode Turn AP mode ON WLAN cartri...

Страница 52: ...5 Home network connection Read out the status of the connection to the home network 1 Go to D 5 Wireless gateway Home network connection 2 Read out the connection status Disconnected from WLAN_SSID C...

Страница 53: ...cessary you can easily deviate from the schedule For shorter periods You can overrule the scheduled room temperature until the next scheduled action Example When you have a party or when you are leavi...

Страница 54: ...fluorinated greenhouse gases Do NOT vent gases into the atmosphere Refrigerant type R32 Global warming potential GWP value 675 NOTICE Applicable legislation on fluorinated greenhouse gases requires th...

Страница 55: ...T leak If the refrigerant leaks in the room and comes in contact with fire from a burner a heater or a cooker this may result in fire or the formation of a harmful gas Turn off any combustible heating...

Страница 56: ...of a malfunction the following will appear on the home screen depending on the severity Error Malfunction You can get a short and a long description of the malfunction as follows 1 Press the left dia...

Страница 57: ...itter type See 5 6 5 To change the desired leaving water temperature 429 The weather dependent curve is set incorrectly Adjust the weather dependent curve See 5 9 Weather dependent curve 442 8 4 Sympt...

Страница 58: ...or boiler if the user activates this via the Malfunctioning main menu screen When the heat pump fails or will appear on the user interface Possible cause Corrective action Heat pump is damaged See 8...

Страница 59: ...urge air from heat emitters or collectors check if or is displayed on the home screen of the user interface If not you can purge air immediately If yes make sure that the room where you want to purge...

Страница 60: ...F Daikin Altherma 3 R ECH O 4P663484 1 2021 07 9 Relocation 9 1 Overview Relocation If you want to relocate parts of your system contact your installer You can find the contact helpdesk number via the...

Страница 61: ...P663484 1 2021 07 10 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Unit...

Страница 62: ...in Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application explainin...

Страница 63: ...nly Backup heater type 9 3 1 Domestic hot water 9 2 1 Emergency 9 5 Number of zones 4 4 Solar 9 2 4 Backup heater Voltage 9 3 2 Configuration 9 3 3 Capacity step 1 9 3 4 Additional capacity step 2 9 3...

Страница 64: ...staller User reference guide 64 EBSH X B 11 16P30 50DF Daikin Altherma 3 R ECH O 4P663484 1 2021 07 12 2 Settings menu Setting Fill in Main zone Thermostat type 2 A Additional zone if applicable Therm...

Страница 65: ......

Страница 66: ......

Страница 67: ......

Страница 68: ...4P663484 1 2021 07 Copyright 2021 Daikin 4P663484 1 0000000T Verantwortung f r Energie und Umwelt...