5
|
About the units and options
Installer reference guide
27
EPRA08~W1 + ETBH/9W
Daikin Altherma 3 H MT W
4P634885-1 – 2021.03
5.2.2 Identification label: Indoor unit
Location
Model identification
Example:
E TB H 12 EA 6V
Code
Description
E
European model
TB
Wall-mounted hydro-split unit with separated tank
H
H=Heating only
X=Heating/cooling
12
Capacity class
EA
Model series
6V
Backup heater model
5.3 Combining units and options
INFORMATION
Certain options may NOT be available in your country.
5.3.1 Possible combinations of indoor unit and outdoor unit
Indoor unit
Outdoor unit
EPRA08
EPRA10
EPRA12
ETBH/X12
O
O
O
5.3.2 Possible combinations of indoor unit and domestic hot water tank
Combination table
Indoor unit
Domestic hot water tank
EKHWS*D*
EKHWSU*D*
EKHWP
Third-party
tank
ETBH/X
O
O
O
O
(a)
(a)
When using a third-party tank, make sure it complies with the minimum requirements (see
"Third-party tank requirements"
27]).
Third-party tank requirements
In case of a third-party tank, the tank shall adhere to the following requirements:
▪
The heat exchanger coil of the tank is ≥1.05 m² and ≤3.7 m².
▪
The tank thermistor must be located above the heat exchanger coil.