9
|
Electrical installation
Installer reference guide
128
EPRA08~W1 + ETSH/X(B)12P30+50EF
Daikin Altherma 3 H MT ECH₂O
4P663478-1 – 2021.07
A
N/- L/+
Alarm output
Max. load
0,3 A - 230 V AC
1 A - 5 V DC
A
B
B
1 2
X 2M
1
1
2
3
Fix the cable with cable ties to the cable tie mountings. General information,
see
"9.3.1 To connect the electrical wiring to the indoor unit"
9.3.9 To connect the space cooling/heating ON/OFF output
INFORMATION
Cooling is only applicable in case of reversible models.
Wires: (2)×0.75 mm²
Maximum load: 0.3 A, 230 V AC
Maximum load: 1 A, 5 V DC
—
1
"7.2.5 To open the indoor unit"
72]):
1
User interface panel
1
3
4
2
2
Switch box
3
Switch box cover
4
Top cover
2
Connect the space cooling/heating ON/OFF output cable to the appropriate
terminals as shown in the illustration below.