9
|
Electrical installation
Installer reference guide
126
EPRA14~18D + ETV23E
Daikin Altherma 3 H HT F
4P644738-1A – 2022.03
A
1~M M2P
B
A
B
1 2
X2M
3
Fix the cable with cable ties to the cable tie mountings.
9.3.6 To connect the alarm output
Wires: (2+1)×0.75 mm²
Maximum load: 0.3 A, 250 V AC
[9.D]
Alarm output
1
"7.2.6 To open the indoor unit"
71]):
1
Top panel
1
2
3
2
User interface panel
3
Upper switch box cover
2
Connect the alarm output cable to the appropriate terminals as shown in the
illustration below.
7 9
YC
Y1
X2M
1
2
3
A4P
1+2
Wires connected to the alarm output
3
Wire between X2M and A4P
A4P
Installation of EKRP1HBAA is
required.