11 Technical data
Installation manual
44
ETV23E
Daikin Altherma 3 H HT F
4P644729-1E – 2023.10
WARNING TO USER
■
Do not remove or adjust any component part of this installation.
Contact the installer.
■
Should the system develop a fault, switch the system off and
contact the installer.
WARNING TO INSTALLER
■
This installation is subject to building regulation approval,
notify Local Authority of intention to install.
■
Use only manufacturer's recommended spare parts.
Contact your local Daikin dealer.
■
Installed by
name
address
tel. No.
completion date
TECHNICAL SPECIFICATIONS
EN12897: 2016
■
Maximum water supply pressure to pressure reducing valve:
16 bar
■
Operating pressure/set pressure of pressure reducing valve:
3.5 bar
■
Maximum primary working pressure (heating):
2.5 bar
■
Maximum flow temperature:
65
o
C
■
Expansion vessel pre-charge pressure:
3.5 bar
■
Expansion valve setting:
8 bar
■
Temperature and pressure relief valve
replacement part No.:
302810P
■
Operating pressure of temperature and pressure
relief valve:
10 bar
■
Operating temperature of temperature and pressure
relief valve:
95
o
C
■
Operating temperature of thermal cut-out (2 pieces):
89
o
C
■
Primary heating power input:
ETVH16SU18EJ6V7
30.05 kW
ETVH16SU23EJ6V7
30.12 kW
■
Primary flow rate to reach primary heating power input:
15 l/min
■
Standing heat loss:
ETVH16SU18EJ6V7
1.35 kWh/
24h
ETVH16SU23EJ6V7
1.76 kWh/
24h
■
Model
storage capacity
mass of unit when full
ETVH16SU18EJ6V7
180 l
289 kg
ETVH16SU23EJ6V7
220 l
338 kg
■
Maximum design pressure:
10 bar
■
Rated volume heat exchanger:
9.1 l
4P709858-1