9
|
Configuration
Installer reference guide
136
EPRA14~W1 + ETVH/9W(G)
Daikin Altherma 3 H HT F
4P587502-1A – 2020.01
9.5.2 Room
Overview
The following items are listed in the submenu:
1
Room
Main zone
Malfunctioning
Operation
Additional zone
[1]
Room
Setpoint screen
[1.1]
Schedule
[1.2]
Heating schedule
[1.3]
Cooling schedule
[1.4]
Antifrost
[1.5]
Setpoint range
[1.6]
Room sensor offset
[1.7]
Room sensor offset
Setpoint screen
Control the room temperature of the main zone via setpoint screen [1]
Room
.
125].
Schedule
Indicate if the room temperature is controlled according to a schedule or not.
#
Code
Description
[1.1]
N/A
Schedule
:
▪
No
: Room temperature is directly controlled by
the user.
▪
Yes
: Room temperature is controlled by a
schedule and can be modified by the user.
Heating schedule
Applicable for all models.
Define a heating schedule of the room temperature in [1.2]
Heating schedule
.
"9.3.7 Schedule screen: Example"
Cooling schedule
Only applicable for reversible models.
Define a cooling schedule of the room temperature in [1.3]
Cooling schedule
.
"9.3.7 Schedule screen: Example"
Antifrost
[1.4]
Antifrost
prevents the room from getting too cold. This setting is
applicable when [2.9]
Control
=
Room thermostat
, but also offers functionality
for leaving water temperature control and external room thermostat control. In
case of the latter two,
Antifrost
can be activated by setting field setting
[2-06]=1.
Room frost protection, when enabled, is not guaranteed when there is no room
thermostat that can activate the heat pump. This is the case when:
▪
[2.9]
Control
=
External room thermostat
and [C.2]
Space heating/
cooling
=
Off
, or if