22
1·6
2·4
2·4
3·5
Factory setting
(With non-standard models, the settings
may be different from the above.)
Example) Capacity direct designation
(Capacity setting: 100%)
Cooling Oil at Constant Capacity (%)
With the above operation setting, the Oil Cooling Unit executes cooling operation according to the specified capacity
command (%). Oil temperature control is disabled.
The capacity setting range is 0 to 100%.
∗
The capacity (%) is an approximate index.
∗
When the capacity is set to “0”%, the compressor stops. (The pump and fan are running.)
∗
Even if the capacity command value is same, the actual cooling capacity varies depending on the room temperature and the inlet oil
temperature.
Operation mode: 9
Setting procedure
Cooling oil at
a constant capacity (%)
• Go to the operation setting mode with the key.
See “
Mode changing operation
” on page .
• The “SETTING” lamp on the operation mode indicator lights.
∗
The number on the operation mode display blinks.
1. Select the operation setting mode.
When the number on the operation mode display is blinking,
change the number to “9” with the or key.
2. Change the operation mode.
After the number is registered, the number on the data display blinks.
∗
“9” on the operation mode display remains lit.
3. After changing the number, press the key
to register it.
After the temperature setting is registered, the number on the
operation mode display blinks.
∗
The number on the data display remains lit.
5. After changing the set value, press the key
to register it.
When the number on the data display is blinking, change the set
value to a desired capacity with the or key.
4. Change the set value.
• Press the key three times, to return to the normal mode.
See “
Mode changing operation
” on page .
• The “NORMAL” lamp on the operation mode indicator lights.
6. Return to the normal mode.
17
17
Caution
The oil temperature is not controlled in the operation mode: 9 and the main unit may be seriously damaged, use the product with extra care.
For example, if the cooling capability insufficient status such as 0% operation is caused at the maximum load or the cooling capability
excessive status like 100% operation is caused at low rotation, operating parts (such as the main shaft) may be damaged or burn out, or fire
may be caused in the worst case.
Data display
Operation mode
display
Operation mode
indicator
Handling
Operating
Pr
ocedure
PIM00318A_EN.fm Page 22 Tuesday, October 26, 2010 12:37 PM
Содержание AKZ149
Страница 2: ...PIM00318A_EN fm Page 0 Tuesday October 26 2010 12 37 PM ...
Страница 45: ...PIM00318A_EN fm Page 43 Tuesday October 26 2010 12 37 PM ...
Страница 46: ...PIM00318A_EN fm Page 44 Tuesday October 26 2010 12 37 PM ...
Страница 47: ...PIM00318A_EN fm Page 45 Tuesday October 26 2010 12 37 PM ...