20
Handling
Operating
Pr
ocedure
Data display
Operation mode
display
Operation mode
indicator
Tank
Outlet oil temperature control
Operation mode: 1
Inlet oil temperature control
Operation mode: 0
Returned oil temperature control
∗
Operation mode: 1
1·6
2·4
2·4
3·5
Holding Constant Oil Temperature
To hold a constant oil temperature, the following two types of operation settings are available.
Controlling
the inlet oil temperature
at a constant temperature
Operation mode: 0
Operation mode: 1
Setting procedure
• Go to the operation setting mode with the key.
See “
Mode changing operation
” on page .
• The “SETTING” lamp on the operation mode indicator lights.
∗
The number on the operation mode display blinks.
1. Select the operation setting mode.
When the number on the operation mode display is blinking,
change the number to “0” or “1” with the or key.
2. Change the operation mode.
After the number is registered, the number on the data display blinks.
∗
The number on the operation mode display remains lit.
3. After changing the number, press the key
to register it.
After the temperature setting is registered, the number on the
operation mode display blinks.
∗
The number on the data display remains lit.
5. After changing the set value, press the key
to register it.
When the number on the data display is blinking, change the set
value to a desired oil temperature with the or key.
4. Change the temperature setting.
∗
Optional function using optional parts. See page .
• Press the key three times, to return to the normal mode.
See “
Mode changing operation
” on page .
• The “NORMAL” lamp on the operation mode indicator lights.
6. Return to the normal mode.
Factory setting
(With non-standard models, the settings
may be different from the above.)
Example) Outlet oil temperature,
Fixed temperature control
(Temperature setting: 25˚C)
Controlling
the outlet (returned) oil temperature
at a constant temperature
35
17
17
PIM00318A_EN.fm Page 20 Tuesday, October 26, 2010 12:37 PM