![Daikin 4MXS-R Series Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/daikin/4mxs-r-series/4mxs-r-series_service-manual_4193026058.webp)
Outdoor Unit
SiUS121736EA
45
Printed Circuit Board Connector Wiring Diagram
Service Monitor
PCB (PCB2)
SW6-2 and all the switches of SW5 have no function. Keep them OFF.
1) S501, S502
Connector for main PCB (PCB1)
2) LED A
LED for service monitor (green)
3) LED1 - LED5
LED for service monitor (red)
4) SW1
Forced operation ON/OFF switch
∗
Refer to page 222 for details.
5) SW2
Operation mode switch
∗
Refer to page 222 for details.
6) SW3
Wiring error check switch
∗
Refer to page 223 for details.
7) SW4
Priority room setting switch
∗
Refer to page 230 for details.
8) SW6-1
NIGHT QUIET mode setting switch
∗
Refer to page 231 for details.
3P346711-10
S502
SW6-1
SW2
SW3
LED5 LED4 LED3 LED2 LED1 LED A
S501
SW1
SW4