5.3.5 MAIN/SUB and Address Setting for Wireless Remote Controller for
FDMQ Series
Outline
If setting multiple wireless remote controllers to operate in one room, perform address setting
for the receiver and the wireless remote controller.
If using both a wired remote controller and a wireless remote controller with 1 indoor unit,
change the MAIN/SUB switch of the signal receiver PCB.
Signal Receiver
PCB Setting
MAIN/SUB switch
Set the MAIN/SUB setting switch (SS1) on the signal receiver PCB to SUB.
Wireless address switch
Set the address setting switch (SS2) on the signal receiver PCB according to the table below.
MAIN
SUB
MAIN/SUB setting
switch (SS1)
Unit No.
No.1
No.2
No.3
Address setting
switch (SS2)
Setting the receiver
(lt is factory set to “1”)
Address setting switch (SS2)
MAIN/SUB setting switch (SS1)
(R24951)
M
S
M
S
1
2
3
1
2
3
1
2
3