Field Settings
SiUS121736EA
247
Trial Operation and Field Settings
Wireless Remote
Controller
Address
Factory set is 1. Change the wireless remote controller address setting by the following steps, if
necessary.
1. Hold down
button and
/TEST button at the same time for at least 4 seconds to enter the
field setting mode. (SETTING is indicated on the display).
2. Press
FAN button and select display setting ( or ). Each time the button is pressed, the
display switches between and .
3. Press
button and
button to set the address.
Address can be set from 1 ~ 6, but set it to 1 ~ 3 and to same address as the transmitter board.
(The transmitter board does not work with address 4 ~ 6.)
4. Press
RESERVE
button to confirm the setting.
5. Hold down
/TEST button to quit the field setting mode and return to the normal display.
Multiple Settings
or
When the indoor unit is controlled by an outside controller (central remote controller, etc.), the
indoor unit sometimes does not respond to ON/OFF command or temperature setting command
from the wireless remote controller. Check what setting the customer needs and make the multiple
setting as shown below.
Field setting mode
Address
Multiple setting
(R14401)
Remote controller
Indoor unit
Multiple settings
Remote controller
display
To control other air
conditions and units
For other than on left
: Standard
All items displayed.
Commands other than
ON/OFF and
temperature setting
accepted.
(1 LONG BEEP or 3
SHORT BEEPS emitted)
All commands accepted.
(2 SHORT BEEPS)
: Multi System
Operations remain
displayed shortly after
execution
All commands accepted.
(2 SHORT BEEPS)
Содержание 4MXS-R Series
Страница 7: ...SiUS121736EA Table of Contents vi 3 Operation Limit 267...
Страница 23: ...SiUS121736EA Specifications 10 Part 2 Specifications 1 RA Indoor Unit 11 2 SA Indoor Unit 19 3 Outdoor Unit 22...
Страница 133: ...SiUS121736EA Wired Remote Controller BRC944B2 Remote Controller 120 6 Wired Remote Controller BRC944B2...