![Daikin 4MXL36TVJU Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/daikin/4mxl36tvju/4mxl36tvju_service-manual-removal-procedure_501132012.webp)
PCB
Si121858E
10
Removal Procedure
[E1], [E2], [E3]: ground
[HL1], [HN1]: power supply
[S], [S10]: to terminal block
[S20](white): room A
[S21](red): room B
[S22](blue): room C
[S23](yellow): room D
[S24](white): room E (5-room
model only)
[S25](red): electronic expansion
valve for bypass
circuit
[S40]: overload protector
[S70]: fan motor
[S80]: four way valve coil
[S90]: thermistor ASSY
[S92]: gas pipe thermistors
[S93]: liquid pipe thermistors
[S201], [S202]: service monitor
PCB
2. Remove the service
monitor PCB.
When reassembling, make
sure that the 2 hooks are
securely fastened.
1
Remove the 2 screws
and remove the shield
plate (right).
2
Remove the screw and
remove the switch
cover.
When reassembling, make
sure that the 2 hooks are
securely fastened.
Step
Procedure
Points
[E3]
[E2]
[HN1]
[HL1]
[E1]
[S10]
[S202]
[S201]
[S40]
[S21]
[S20]
[S93]
[S25] [S90]
[S92]
[S22]
[S23][S24]
Main PCB
[S70]
[S80]
[S]
(R25776)
Shield plate (right)
(R25777)
(R25778)
Switch cover
(R25779)
Hook
(R22310)