![Daikin Altherma EHVH04SU18CB6W Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/daikin-altherma/ehvh04su18cb6w/ehvh04su18cb6w_installation-manual_3205368006.webp)
4 Installation
Installation manual
6
08SU EHVH08~16SU26CB6W
Daikin Altherma – Low temperature split
4P449980-1B – 2016.11
4.2
Mounting the indoor unit
4.2.1
To install the indoor unit
1
Lift the indoor unit from the pallet and place it on the floor.
120kg
4×
2
Slide the indoor unit into position.
3
Adjust the height of the leveling feet to compensate for floor
irregularities. The maximum allowed deviation is 1°.
≤1°
NOTICE
Do NOT tilt the unit backwards:
0°
1°
1°
4.3
Connecting the refrigerant piping
See the outdoor unit installation manual for all guidelines,
specifications and installation instructions.
4.3.1
To connect the refrigerant piping to the
indoor unit
1
Connect the liquid stop valve from the outdoor unit to the
refrigerant liquid connection of the indoor unit.
b a
a
Refrigerant liquid connection
b
Refrigerant gas connection
2
Connect the gas stop valve from the outdoor unit to the
refrigerant gas connection of the indoor unit.