4.3.3 Adjustment of the coaxial power cable (AII-B4)
(1) Mount a torch, wire feeding unit (fixing bracket), and coaxial power cable.
(2) Operate the 5
th
axis to the maximum (soft limit) toward the manipulator’s inner side as
shown in Fig.4.9.
(3) Operate the 6
th
axis to the maximum (soft limit). (Either in the + or – side.)
(4) Adjust the fixing bracket in the above posture so that the coaxial power cable does
not collide with the cover (see Fig.4.9).
Fig.4.9 Adjustment of the coaxial power cable
4.4 Cutting the Liner
Cut the liner according to the length of each torch, referring to Fig. 4.10 and Table 4.4, Fig4.11 and
Table 4.5.
Rasp the edge of the liner’s cut section to eliminate burrs.
Also, take enough care not to bend a liner or burr the hole when cutting.
Fig.4.10 Cutting the liner
Fig.4.11 Cutting the liner
Note) The liner cutting length is common to
AII -B4 type and AII -V6 type.
Table 4.4 Length of liner (Rough measure)
Torch model
L (mm)
RT3500S 291
RT3500H 360
RT3500L 331
RT5000S 274
RT5000H 343
RT5000L 314
RTW5000S 288
RTW5000H 356
RTW5000L 338
RZ3500S 207
RZ3500H 277
RZ3500L 263
一線式パワーケーブル
カバー
トーチ
固定ブラケット
ワイヤ送給装置
Coaxial power cable
Wire feeding unit
Cover
Torch
Fixed feeding unit
Table 4.5 Length of liner (Rough measure)
Torch model
L
(
mm
)
RT3500S 128
RT3500H 197
RT3500L 168
RT5000S 111
RT5000H 180
RT5000L 151
RTW5000S 124
RTW5000H 193
RTW5000L 174
RZ3500S 44
RZ3500H 115
RZ3500L 100
Coaxial power cable
Liner
Liner
Nozzle holder