18
-
3.2.6 Adjustment procedure with the tool length automatic setting
(1) Copy the existing origin position check program (Program “A” for example), and newly create
the program B. Running this program B, align the tip of reference gauge and the point of tip
gauge fixed on the torch tip by performing the
rectangular manual operation holding the
torch posture
from the position of program A to perform teaching (point-teaching).
Fig.3.14 Checking the reference point
(2) Perform the 2-point tool length setting. With this setting, the amount of torch (tool) deviation
can be automatically reflected to the program. For details of the operation procedure, see the
instruction manual; section 4.5.2 “Tool length” in INSTALLATION.
(3) As the tool conversion function is automatically executed, follow the instruction and convert
the program that you would like to perform the tool conversion. For details of the operation
procedure, see the instruction manual; section 4.5.8 “Tool conversion” in INSTALLATION.
(4) Call the program A and check that the deviation in the reference point (2) has been corrected,
having a proper reference point.
In addition, do not execute the tool conversion function in the program where the reference point
(1) has been taught with the optional gauge ASSY provided.
If executing the tool conversion function in all the programs, teach the reference point (1) again.
Reference Point
(2)
Reference point (2) before
the positional deviation occured
(Program A)
Taught reference point
(Program A)
Gap
Corrected reference point
(Program B)
Hit the torch and a gap occurs.