background image

 

DAIHAN-Sci.com or 

ALL 

for

 

LAB.com

 

 

Shopping Mall

 

 

 

Digital Jar Tester                                                                                                                                                               

2 /40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

European Declaration of Conformity

 

 
 
 

We, DAIHAN Scientific Co., Ltd., 

Daihan Bldg., 24-4, Sangwolgok-dong, Seongbuk-gu, Seoul, Korea, 

Tel: 82-2-967-5235, Fax: 82-2-963-5231 

declare under our sole responsibility that the product 

 
 

Jar Tester 

JT-M6C 

 

to which this declaration relates is in conformity 

with the following standard or other normative document 

 

EN 61326            EN 61000-3-2, EN 61000-3-3 

EN 61010-1, EN 61010-2 

 

 

following the provisions of the directives: 

 

Low-Voltage Directive 2006/95/EC 

                    EMC Directive 2004/108/EC

 

 

EC Directive 2006/42/EC 

RoHS - Directive 2011/65 EU 

 
 
 
 

 

Signed: ____________________________    (Eun Taek Shu) 
 
 
Date:            27, March 2015 

Authority:    President / CEO 

 

For 

 
 

DAIHAN Scientific Co., Ltd. 

Daihan Bldg., 24-4, Sangwolgok-dong, Seongbuk-gu, Seoul, Korea. 

Tel: 82-2-967-5235, Fax: 82-2-963-5231 

 
 

DH-DC09035-R02

 

Содержание JT-M6C

Страница 1: ...ed Products ISO 9001 Certified PL Insurance Patented No 10 0554098 Jog Shuttle Control System Operation Manual Version 2 1 1 written for JT M6C models JT M6C Digital Jar Tester Sales Basic A S By the...

Страница 2: ...ion relates is in conformity with the following standard or other normative document EN 61326 EN 61000 3 2 EN 61000 3 3 EN 61010 1 EN 61010 2 following the provisions of the directives Low Voltage Dir...

Страница 3: ...ents Page 1 Safety Instructions 4 2 Before Use 8 3 Introduction 9 4 Package Contents 10 5 Appearance and Naming 10 6 Installation 11 7 Cautions in Use 13 8 Controller Details 15 9 Operation 16 10 Spec...

Страница 4: ...he risk of explosion or fire This symbol indicates the user must be kept away while operation This Symbol indicates that this product is to be collected separately The following apply only to users in...

Страница 5: ...y When you connect the product specified with 100V to 200V or vice versa it may be caused to over heat electric shock or a short circuit to each part Do not connect wrong electricity since it is the c...

Страница 6: ...device as not to release heat or insufficient ventilation may result Set the device a lightening place When you set the device at a dark place it may cause an unexpected accident by mistake in operati...

Страница 7: ...main plug and contact manufacturer or a supplier CAUTION This device must be connected to an earthed power supply If you use radiation or contaminated samples the responsibility is to the customer Do...

Страница 8: ...e without notice to improve the quality and performance of the product Product Liability PL Insurance Admission DAIHAN Scientific Co Ltd is a member of Product Liability Insurance PL Insurance so that...

Страница 9: ...ce for each Stirring Point make a same condition of lights n Digital Feedback Control using Microprocessor n Geared DC Motor and Specially Designed Timing Belt used n Stable and Accurate Stirring Spee...

Страница 10: ...orLAB com Shopping Mall Digital Jar Tester 10 40 Package Contents 4 Jar Tester Power Cord Operation Manual Appearance and Naming 5 The appearance of Digital Jar Tester Figure 1 Appearance of JT M6C Co...

Страница 11: ...vice on a level horizontal surface to support the capacity of the device without vibration If there is vibration install the device on a support material with enough space Small place may cause the de...

Страница 12: ...ce should be set at a well ventilated place Be sure the holes on the side or rear surface of the body are blocked by a wall or an object And do not operate the device at a poor ventilated place or use...

Страница 13: ...s generated pull out the mains plug and contact manufacturer or a supplier Avoid allowing objects to push or strike the hotplate or stirring plate of the machine The hotplate is made of ceramic coated...

Страница 14: ...hand while operation Do not turn on and off frequently It could damage the electric parts of machine CAUTION This device must be connected to an earthed power supply If you use radiation or contamina...

Страница 15: ...LCD Set Program Measured RPM Current Power Bar Graph indicating the power of motor operating Main Power Switch JOG Dial Knob Setup of stirring Timer and set Program by Turning and then Start Stop by...

Страница 16: ...urrently through B If the set RPM is non zero it means someone has saved a RPM value previously You can use the saved RPM by click the jog shuttle switch If you would like to change the saved value yo...

Страница 17: ...g and then push a jog shuttle button for goes to running speed setting After set a running speed by jog shuttle turning Push a SET button for save this step Use with 5 6 function button for goes to ne...

Страница 18: ...running once more B When running a program If you want to cancel operation Push a MODE button a Setting mode b Select program c Start of setting d Time setting e Speed setting f Speed adjust g Save a...

Страница 19: ...er load due to over the capacity Temperature Sensing 2 When Jar Tester goes into an abnormal operating condition such as a over condition and being prohibited by unexpected obstacles in the roller the...

Страница 20: ...DAIHAN Sci com or ALL forLAB com Shopping Mall Digital Jar Tester 20 40 Specifications 10...

Страница 21: ...rranty sheet included in this operation manual breakdown of the machine in spite of normal proper use will be treated by manufacturer or by an official agent of manufacturer 4 The manufacturer or its...

Страница 22: ...d Solutions Not stirring Check the Set RPM Check if the MAIN power switch is ON Power failure Check if the power cord is plugged Check if the supplied electricity is proper and regulated Check the fus...

Страница 23: ...pment 2 This instrument is warranted for 2 years from purchasing date 3 A breakdown caused by customer s improper use or natural disaster is excepted from this warranty 4 This certification is only fo...

Отзывы: