Local Setting 10
4.3.1 Local
On the main interface (Figure 3-1), select
Local Setting > Access Control > Local
.
Step 1
The
Local
interface is displayed. See Figure 4-3.
Local
Figure 4-3
Configure parameters, and for the detailed description, see Table 4-3.
Step 2
Table 4-3 Local access control parameter description
Parameter
Description
Unlock Responding
Interval
The time interval to unlock again after the previous unlock, and the
unit is second.
Unlock Period
The time amount for which the lock stays open after unlock, and
the unit is second.
Door Sensor Check
Time
If you have installed door sensor, then you can configure the time
period, and If the unlock time exceeds the
Door Sensor Check
Time
, the door sensor alarm is triggered, and the alarm will be sent
to the management center.
Select the
Enable
check box, and the door will not be locked
until the door sensor contacts each other.
If you do not select the
Enable
check box, the door will be
locked after the
Unlock Period
finishes.
Issue Card Password
This password can be used to issue new card.
This password is only for admin people or engineer.
It is 888888 by default.
Project Password
It can be used to go to the engineering interface, and it is 888888
by default.
Project password is only for admin people or engineers.
First Unlock
Command
You can connect a third-party phone such as SIP phone to your
VTO, and use the command to open the door remotely.
Door Contact Type
Select
NC
or
NO
according to the lock you use.
Public Unlock
Password
Select the
Enable
check box, then configure the public unlock
password, and then all the residents in this unit can open the door
with this password.
Public Unlock
Password Confirm