Figure 2-15
2.7.2.3
Alarm Cable Connection
The alarm cable connection mode and config steps are shown as follows:
Step 1
Connect alarm input device to the ALARM_IN and ALARM_GND of the user cable.
Step 2
Connect alarm output device to the ALARM_OUT and ALARM_COM of the user cable, alarm
output is the relay switch output.
Step 3
Open the device WEB interface, make corresponding settings to the alarm input and output
devic
e in “Setup > Event > Alarm Setup". The alarm input of WEB is corresponding to the alarm
input of the user cable. It is to set the corresponding NO and NC output according to the high and
low level signal generated by alarm input device when alarm triggers.
Step 4
Set the alarm output situation of user cable on the WEB.
2.7.2.4
Connect Speed Dome GND Cable
Connect the power line YELLOW/GREEN of the combination cable to the lightning protection
device, and make sure the lightning protection device is well grounded.
2.7.3 Install the speed dome
Step 1
Pull the integration cable and multiple-function composite cable to the wall mount bracket slowly.
Step 2