background image

 

Cybersecurity  Recommendations  II

 

 

 

  Cybersecurity Recommendations 

Mandatory actions to be taken towards cybersecurity

 

 

1. Change Passwords and Use Strong Passwords:

 

The number one reason systems get “hacked” is due to having weak or default passwords. It is 

recommended  to  change  default  passwords  immediately  and  choose  a  strong  password 

whenever  possible.  A  strong  password  should  be  made  up  of  at  least  8  characters  and  a 

combination of special characters, numbers, and upper and lower case letters. 

 

2. Update Firmware

 

As  is  standard  procedure  in  the  tech-industry,  we  recommend  keeping  NVR,  DVR,  and  IP 

camera firmware up-to-date to ensure the system is current with the latest security patches and 

fixes. 

 

“Nice to have” recommendations to improve your network security

 

 

1. Change Passwords Regularly

 

Regularly change the credentials to your devices to help ensure that only authorized users are 

able to access the system. 

 

2. Change Default HTTP and TCP Ports:

 

●  Change  default  HTTP  and  TCP  ports  for  systems.  These  are  the  two  ports  used  to 

communicate and to view video feeds remotely. 
●  These  ports  can  be  changed  to  any  set  of  numbers  between  1025-65535.  Avoiding  the 

default ports reduces the risk of outsiders being able to guess which ports you are using. 

 

3. Enable HTTPS/SSL:

 

Set up an SSL Certificate to enable HTTPS. This will encrypt all communication between your 

devices and recorder. 

 

4. Enable IP Filter:

 

Enabling  your  IP  filter  will  prevent  everyone,  except  those  with  specified  IP  addresses,  from 

accessing the system. 

 

5. Change ONVIF Password:

 

On  older  IP  Camera  firmware,  the  ONVIF  password  does  not  change  when  you  change  the 
system’s credentials. You will need to either update the camera’s firmware to the latest revision 

or manually change the ONVIF password. 

 

6. Forward Only Ports You Need:

 

Содержание DHI-ASC1204C

Страница 1: ...Four door One way Access Controller User s Manual V1 0 0...

Страница 2: ...egularly change the credentials to your devices to help ensure that only authorized users are able to access the system 2 Change Default HTTP and TCP Ports Change default HTTP and TCP ports for system...

Страница 3: ...stem is set up for multiple users ensure that each user only has rights to features and functions they need to use to perform their job 10 UPnP UPnP will automatically try to forward ports in your rou...

Страница 4: ...ras to the PoE Ports on the Back of an NVR Cameras connected to the PoE ports on the back of an NVR are isolated from the outside world and cannot be accessed directly 16 Isolate NVR and IP Camera Net...

Страница 5: ...these limits are designed to provide reasonable protection against harmful interference in a commercial environment Operation of this equipment in a residential area is likely to cause harmful interf...

Страница 6: ...ight collect personal data of others such as face fingerprints car plate number Email address phone number GPS and so on You need to be in compliance with the local privacy protection laws and regulat...

Страница 7: ...ations description or errors in print If there is any doubt or dispute please refer to our final explanation Upgrade the reader software or try other mainstream reader software if the Manual in PDF fo...

Страница 8: ...output range Please don t dismantle the device arbitrarily Please transport use and store the device within allowed humidity and temperature range Power Requirement Please make sure to use batteries...

Страница 9: ...10 2 4 Restart 10 2 5 3 SmartPSS Config 11 Login Client 11 3 1 Add Access Controller 11 3 2 3 2 1 Auto Search 11 3 2 2 Manual Add 13 Add User 15 3 3 3 3 1 Card Type 16 3 3 2 Single Add 17 Add Door Gro...

Страница 10: ...Table of Contents X 8 Question Max wiring distance and transmission distance of card reader and controller 24 5 Technical Parameters 25...

Страница 11: ...tton 4 door contact 4 intrusion alarm 1 and tamper alarm 1 Support 5 groups of control output electric lock 4 and alarm output 1 With RS485 port it may extend to connect control module FLASH storage c...

Страница 12: ...Overview 2 Figure 1 1...

Страница 13: ...de System Structure 2 1 System structure of four door one way access controller door lock and reader is shown in Figure 2 1 Figure 2 1 Device Installation 2 2 Device installation diagram is shown in F...

Страница 14: ...al weight of the device bracket and accessories Measure every hole distance and position according to holes at rear shell of the device Step 1 as shown in Figure 2 3 drill holes in the wall according...

Страница 15: ...ase of alarm input trigger external alarm output device to give an alarm Device wiring diagram is shown in Figure 2 4 Figure 2 4 2 3 2 Wiring Description of Exit Button Door Contact Corresponding wiri...

Страница 16: ...nput of door 2 SR2 Door contact input of door 2 PUSH3 Exit button of door 3 GND Shared by exit button of door 3 and door contact input of door 3 SR3 Door contact input of door 3 PUSH4 Exit button of d...

Страница 17: ...Please refer to Table 2 2 for descriptions of wiring terminals Figure 2 6 Figure 2 7 Figure 2 8 Table 2 2 Port Wiring Terminal Description Lock control output port NC1 Lock control of door 1 COM1 NO1...

Страница 18: ...ring Terminal Cable Color Description Entry Reader of Door 1 485 Purple 485 reader 485 Yellow LED Brown Wiegand reader D0 Green D1 White CASE Blue GND Black Reader power supply 12V Red Table 2 4 Reade...

Страница 19: ...igure 2 10 and Figure 2 11 Please refer to Table 2 6 for descriptions about wiring terminals Figure 2 10 Figure 2 11 Table 2 6 Port Wiring Terminal Description Alarm output OUT1 ALM IN triggers alarm...

Страница 20: ...ion meaning 1 the switch is at the bottom meaning 0 1 8 are all 0 the system is started normally 1 8 are all 1 the system enters BOOT mode after start 1 3 5 and 7 are 1 while others are 0 After restar...

Страница 21: ...es for different versions Please refer to actual interface Login Client 3 1 Install the matching Smart PSS client and double click to run Carry out initialization configuration according to interface...

Страница 22: ...e device that needs to be added and click Add Step 3 The system pops up Prompt Click OK Step 4 The system displays Login Information dialogue box as shown in Figure 3 3 Figure 3 3 Input User Name and...

Страница 23: ...Modify Device interface Click this icon to enter Device Config interface and configure device camera network event storage and system info and When the device is online the icon is Click this icon to...

Страница 24: ...fill in according to actual conditions Group Name Select the group of the device User Name and Password User name and password of the device Click Add to add a device Step 3 The system displays the ad...

Страница 25: ...SmartPSS Config 15 Figure 3 7 Add User 3 3 Add users and bind with cards so as to distribute authority In New interface click Access to enter Access interface and complete access config here...

Страница 26: ...16 Figure 3 8 3 3 1 Card Type Card type shall be the same with card issuer otherwise it fails to read card number In Access interface click and then click to set the card type as shown in Figure 3 9...

Страница 27: ...ure 3 9 Figure 3 10 3 3 2 Single Add Add a single user send a card and input user info In Access interface click and then click as shown in Figure 3 11 Step 1 The system pops up Add User dialog box as...

Страница 28: ...SmartPSS Config 18 Figure 3 11 Figure 3 12 Add user info manually including basic info fingerprint info and details Please refer to Step 2 Table 3 3 for details...

Страница 29: ...e it only applies to guest card Valid Time set the valid time of card which is 10 years by default Picture user picture max 120K Card no and user ID cannot be repeated Fingerprint Info Collect fingerp...

Страница 30: ...SmartPSS Config 20 Figure 3 13 Click Add Step 2 The system pops up Add Door Group dialog box as shown in Figure 3 14 Figure 3 14...

Страница 31: ...to Door Group Select a door group add corresponding users to the group so all users in the group obtain authority of all doors in the group In Access interface click and then click Access Level as sho...

Страница 32: ...Step 5 The search list filters user info without card number In the user list cancel the added user and delete the user s authority 3 5 2 Authorize According to User Select a user distribute door grou...

Страница 33: ...SmartPSS Config 23 Figure 3 17 Click Step 2 The system pops up Select Door Group dialog box as shown in Figure 3 18 Figure 3 18 Select the door group and click OK to finish authorization Step 3...

Страница 34: ...ect the device Answer Please check whether TCP IP connector is connected properly and whether device IP is in the same network segment 4 Question After swiping card it prompts that card is invalid Ans...

Страница 35: ...ng power supply Rated voltage 10V 15V DC rated current 0 75A Period 128 Holiday 128 Unlocking mode Card card password password card or password card fingerprint fingerprint password fingerprint or car...