background image

 

4 Wiring 

4.1 Connecting GND 

 

GND cables do not come with the package of select models. Purchase them as needed. 
Grounding the Switch can protect it against lightning and interference. The steps for connecting the 
GND are as follows: 
Step 1 

Remove the ground screw from the Switch and pass the ground screw through the round 
hole of the OT terminal of the ground cable. Turn the ground screw clockwise with a cross 
screwdriver to fasten the OT terminal of the ground cable. 

Step 2 

Wind the other end of the ground cable into a circle with the needle-nose pliers. 

Step 3 

Connect the other end of the ground cable to the ground bar, then turn the hex nut 
clockwise with a wrench to fasten the other end of the ground cable to the ground 
terminal. 

Figure 4-1 Connect GND 

 

4.2 Connecting Power Cord 

Before connecting the power cord, make sure that the Switch is securely grounded. 
Step 1 

Connect one end of the power cord to the power jack of the Switch. 

Step 2 

Connect the other end of the power cord to the external power socket. 

4.3 Connecting SFP Ethernet Port 

Step 1 

We recommend wearing antistatic gloves, and then the anti-static wrist strap before 
installing SFP module. Make sure that the anti-static wrist strap and the antistatic gloves 
are in good contact. 

Step 2 

Lift the handle of the SFP module upward vertically, and stick it to the top hook. Hold the 
SFP module by both sides, and push it gently into the SFP slot till the SFP module is firmly 
connected to the slot (You can feel that both the top and bottom spring strip of the SFP 
module are firmly stuck with the SFP slot). 

Содержание D-PFS3110-8ET1GT1GF-96

Страница 1: ...Dahua Ethernet Switch 4 8 port Unmanaged Desktop Switch Quick Start Guide V1 0 0 ...

Страница 2: ...r or data controller you might collect the personal data of others such as their face fingerprints and license plate number You need to be in compliance with your local privacy protection laws and regulations to protect the legitimate rights and interests of other people by implementing measures which include but are not limited Providing clear and visible identification to inform people of the ex...

Страница 3: ...f there is any doubt or dispute we reserve the right of final explanation Upgrade the reader software or try other mainstream reader software if the manual in PDF format cannot be opened All trademarks registered trademarks and company names in the manual are properties of their respective owners Please visit our website contact the supplier or customer service if any problems occur while using th...

Страница 4: ...away from dampness dust and soot Put the device in a well ventilated place and do not block its ventilation Use an adapter or cabinet power supply provided by the manufacturer The power supply must conform to the requirements of ES1 in IEC 62368 1 standard and be no higher than PS2 Please note that the power supply requirements are subject to the device label Do not connect the device to two or mo...

Страница 5: ...ons Do not drop or splash liquid onto the device and make sure that there is no object filled with liquid on the device to prevent liquid from flowing into it Operating temperature 10 C 14 F to 55 C 131 F This is a class A product In a domestic environment this may cause radio interference in which case you may be required to take adequate measures Do not block the ventilator of the device with ob...

Страница 6: ...1 2 Port and Indicator 2 2 1 Front Panel 2 2 2 Rear Panel 4 3 Installation 5 3 1 Preparation 5 3 2 Desktop Mount 5 3 3 Wall Mount 5 4 Wiring 6 4 1 Connecting GND 6 4 2 Connecting Power Cord 6 4 3 Connecting SFP Ethernet Port 6 4 4 Connecting Ethernet Port 8 4 5 Connecting PoE Port 8 Cybersecurity Recommendations 9 ...

Страница 7: ...nt which can adapt to the fluctuation of power consumption of terminal device to ensure stable operation The Switch is an unmanaged switch so it does not need to be configured through web page which simplifies installation The Switch is applicable for use in in a variety of scenarios such as in the home and office on server farms and in small malls 1 2 Features 4 8 100 1000 Mbps Ethernet port Upli...

Страница 8: ...ingle port connection or data transmission status indicator Link Act On Connected to device Off Not connected to device Flashes Data transmission is in progress 2 PoE port status indicator On Powered by PoE Off Not powered by PoE 3 Single port data transmission status indicator Act Flashes Data transmission is in progress Off No data transmission 4 Single port connection status indicator Link On C...

Страница 9: ...llowing are all the ports and indicators on the front panel of the 8 port unmanaged desktop switch with optical ports and might differ from the actual product Table 2 1 Description of front panel with optical ports No Description 1 PoE port status indicator On Powered by PoE Off Not powered by PoE 2 Single port connection or data transmission status indicator Link Act On Connected to the Switch Of...

Страница 10: ... to 250 m but reduces average transmission speed to 10 Mbps 2 2 Rear Panel The following figure is for reference only and might differ from the actual product Figure 2 2 Rear panel Table 2 2 Description of rear panel No Description 1 Ground terminal Available for certain models 2 Lock hole Used to lock the Switch Available for certain models 3 Power port supports 48 57 VDC ...

Страница 11: ...oles of the Switch Screws do not come with the package Purchase them as needed Make sure that the distance between the screws is the same as the distance between the wall mount holes the distance of the 4 port unmanaged desktop switch is 77 8 mm 3 06 inch the distance of the 8 port unmanaged desktop switch without optical ports is 128 4 mm 5 06 inch and the distance of the 8 port unmanaged desktop...

Страница 12: ... other end of the ground cable to the ground terminal Figure 4 1 Connect GND 4 2 Connecting Power Cord Before connecting the power cord make sure that the Switch is securely grounded Step 1 Connect one end of the power cord to the power jack of the Switch Step 2 Connect the other end of the power cord to the external power socket 4 3 Connecting SFP Ethernet Port Step 1 We recommend wearing antista...

Страница 13: ...part of the SFP module when installing the SFP optical module We do not recommend extracting the dustproof plug of the SFP module before connecting to the optical fiber cable We do not recommend directly inserting the SFP module into the slot Unplug the optical fiber before installation Figure 4 2 SFP module structure Table 4 1 Structure description No Description 1 Gold finger 2 Optical fiber por...

Страница 14: ...t pin number Figure 4 5 Pin description The cable connection of RJ 45 connector conforms to the 568B standard 1 orange white 2 orange 3 green white 4 blue 5 blue white 6 green 7 brown white 8 brown 4 5 Connecting PoE Port You can directly connect the Switch PoE Ethernet port to the device PoE Ethernet port through network cable to achieve synchronized network connection and power supply With Exten...

Страница 15: ...d personnel from carrying out physical contacts such as damaging hardware unauthorized connection of removable device such as USB flash disk serial port etc 2 Change Passwords Regularly We suggest that you change passwords regularly to reduce the risk of being guessed or cracked 3 Set and Update Passwords Reset Information Timely The device supports password reset function Please set up related in...

Страница 16: ...uthorization Check device log By viewing the logs you can know the IP addresses that were used to log in to your devices and their key operations 12 Network Log Due to the limited storage capacity of the device the stored log is limited If you need to save the log for a long time it is recommended that you enable the network log function to ensure that the critical logs are synchronized to the net...

Страница 17: ...1 ...

Отзывы: