16
Step 2. Set zone status of each zone.
Non-bypass: Zone can alarm in this status.
Bypass: The zone is temporarily shielded, when device arm again after be ing disarmed,
the bypass zone will go armed.
Isolated: The zone is stopped, when device arm again after being disarmed, it will
remain stopped.
Note:
These zones cannot be bypass: fire zone, 24-hour sound/mute zone, emergency zone.
Step 3. Select arm type, and arm zones. Click OK. See
Chart 4- 1
.
Step 4. Input username and password, to confirm.
If successfully arm, device will have prompt sound, enter exit delay status, according to set
exit delay, prompt once every 1s, and prompt twice every 1s in the last 10s.
If failed to arm, then device will prompt three times continuously. Now you need to check for
zone input, and you can force to arm.
Arm type, function and scene application are shown below:
Arm Type
Description
Application
Global Arm
Exit delay, entry delay
forbidden, all zones are under
warning status after being
armed
Such as housing being vacant for
period of time (eg vacation, etc.), you
need to close all zones before arming
Instant Arm
Exit delay, entry delay
forbidden; after being armed,
internal track, internal delay
zone will auto be bypassed
When users do not go out and expect
no one is using the entrance, you
need the user to close all doors and
windows before arming. For example,
rest at home
Out Mode
Exit delay, enable entry delay,
all zones are under warning
status after being armed
When no one left in the house used to
be closed before arming all zones
Home Arm
Exit delay, enable entry delay,
after being armed, internal
track, internal delay zone will
auto be bypassed
When the user does not have to go
out, but the person may be expected
to be used later on import and export
use, before arming requires the user
to close up all the doors and windows
Auto Arm
Exit delay, entry delay
forbidden of zones with auto
bypass ON (except 24-hour
zone), 8 periods for auto
arming
Users want the system to
automatically arm use, business on
the Standard, such as company after
work, to a certain point in time the
system will automatically arm
Forced Arm
Exit delay, entry delay
forbidden of zones with auto
bypass ON (except 24-hour
zone)
When a user does not want to deal
with the problem has been the use of
the zone
Chart 4- 1
Note:
Enter delay and exit delay refer to Ch 4.3.2.
When you successfully armed, you cannot change parameters of zone setup, network,
event and all other parameters in menu.