background image

 

 

1  Welcome 

This manual offers reference material and general information about the basic operation, 

maintenance, and troubleshooting of the Dahua Multi-Sensor Panoramic Camera. Read, follow, and 

retain the following safety instructions. Heed all warning on the unit and in the operating instructions 

before operating the unit. Keep this guide for future reference. 

1.1  Important Safeguards and Warnings  

Electrical safety 

 

Install the unit in accordance with the manufacturer’s instructions and in accordance with 

applicable local codes.  

 

All installation and operation must conform to your local electrical safety codes.  

 

Do not overload outlets and extension cords, which may cause fire or electrical shock. 

 

Do not place the camera near or in a place where the camera may contact overhead power lines, 

power circuits, or electrical lights. 

 

All input/output ports are SELV circuits. Ensure that SELV circuits are connected only to other 

SELV circuits.  

 

Ground the unit using the ground connection of the power supply to protect the unit from damage, 

especially in damp environments. 

 

Protect the plug and power cord from foot traffic, being pinched, and its exit from the unit. 

 

Units with or without an ON/OFF switch have power supplied to the unit whenever the power 

cord is inserted into the power source; however, the unit is operational only when the ON/OFF 

switch is in the ON position. The power cord is the main power disconnect device for switching 

off the voltage for all units.  

 

Operate the unit only from the type of power source indicated on the label. Before proceeding, 

disconnect the power from the cable to be installed into the unit.  

  For external power supplied units, use only the recommended or approved power supplies. 

  Limited power sources must comply with EN 60950. Substitutions may damage the unit or 

cause fire or shock. 

  For 24 VAC units, voltage applied to the unit’s input power should not exceed ±25%. User-

supplied wiring must comply with local codes (Class 2 power levels). Do not ground the 

supply at the terminals or at the unit’s power supply terminal.  

  Contact the local dealer or the power company to verify the correct power supply.  

 

Do not supply power via the Ethernet connection (PoE) when power is already supplied via the 

power connector.  

 

Do not attempt to service the unit. Opening or removing covers may expose you to dangerous 

voltage or other hazards. Refer all servicing to qualified personnel. 

 

If the unit is damaged and requires service, unplug the unit from the main AC power supply and 

from the PoE supply and refer to qualified service personnel. Damage may include, but is not 

limited to: 

  The power supply cord or plug is damaged. 

  Liquid has spilled in or on the unit. 

  An object has fallen on the unit. 

  The unit has been dropped and the housing is damaged. 

Содержание A83ALBZ

Страница 1: ...Multi sensor HDCVI Panoramic IR Bullet Camera DH HAC PFW3601N A180 Quick Start Guide Version 001 001 Dahua Technology USA Inc...

Страница 2: ...mpliance 4 1 3 Legal Notices 4 Copyright 4 Trademarks 4 1 4 Disclaimer 5 2 Unpacking 6 3 Installation and Configuration 7 3 1 External Cable 7 Cable Connections 7 Alarm I O Port Configuration 7 3 2 Fr...

Страница 3: ...source however the unit is operational only when the ON OFF switch is in the ON position The power cord is the main power disconnect device for switching off the voltage for all units Operate the uni...

Страница 4: ...ct the longevity of the CCD or the CMOS sensor Transport use and store the unit within the specified temperature and humidity range Do not place the unit in a wet dusty extremely hot or an extremely c...

Страница 5: ...h or wipe a dome cover during installation this cover is an optical device Refer to the following methods clean the dome cover Stained with dirt Use an oil free soft brush or blower to gently remove t...

Страница 6: ...ee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off...

Страница 7: ...y information Dahua accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between this guide and the product described Dahua is not liable for an...

Страница 8: ...tative The original packing carton is the safest container to transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please re...

Страница 9: ...ut Refer to Table 3 2 for more details 5 POWER Power input port Power port Input 12 VDC power Use power according to the device tag Table 3 1 Alarm I O Port Configuration Port Name Color Name Note I O...

Страница 10: ...put signal is grounded then no alarm input signal is detected Figure 3 2 Alarm Output The ALARM_OUT and the ALM_OUT_GND ports form a switch which is used to provide alarm output Normally the switch is...

Страница 11: ...nsation does not form in the mount or the conduit 4 1 Installing the Camera 1 Remove the camera the mounting template multi purpose tool and the hardware package from the box 2 Remove the bottom cover...

Страница 12: ...lti purpose Tool to loosen the three set screws along the shaft of the camera then position the camera by tilting twisting and rotating the camera as shown in the figure below Note Do not rotate the c...

Страница 13: ...DVR 2 From the DVR select the Main Menu and choose Setting Then select the System tab and select the PTZ link on the left side menu 3 Select the appropriate channel number for the camera 4 Set CONTROL...

Страница 14: ...AUDIO SOURCE as HDCVI Figure 5 2 9 Click Save to store the changes 10 Click the right mouse button and select PTZ Control The HDCVI DVR opens the PTZ Setup menu Figure 5 3 11 Click the Camera icon to...

Страница 15: ...e to access the camera s menu Button Function Access the camera s settings menu Select a menu item Select a setting value Adjust lens zoom and auto trigger function Adjust lens focus Trigger autofocus...

Страница 16: ...il from the dome cover Then use an oil free cotton cloth or paper soaked with alcohol or detergent to clean the lens from the center of the dome to outside Change the cloth several times to ensure the...

Страница 17: ...logy USA Inc 23 Hubble Irvine CA 92618 Tel 949 679 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 001 2017 Dahua All rights reserved Design and specifications are subject to change...

Отзывы: