background image

 

 

4  Device Installation  

This section details installing the Multi-Sensor camera to a wall or to a ceiling. Note that the wall or 

ceiling must be capable of supporting a minimum of three (3) times the weight of the camera and a 

bracket (if used).  

Warning

: DO NOT connect the camera to the power supply during installation. 

Warning

: For units intended to be installed outdoors: All wiring connecting to the unit must be routed 

separately inside a different permanently earthed metal conduits (not supplied). 

Warning

: Install external interconnecting cables in accordance to NEC, ANSI/NFPA70 (for US 

application) and Canadian Electrical Code, Part I, CSA C22.1 (for CAN application) and in 

accordance to local country codes for all other countries. Branch circuit protection incorporating a 20 

A, 2-pole Listed Circuit Breaker or Branch Rated Fuses are required as part of the building installation. 

A readily accessible 2-pole disconnect device with a contact separation of at least 3 mm must be 

incorporated. 

Warning: 

DO NOT remove the protective film from the dome until the installation is complete to 

protect the dome from distortions from fingerprints, oil, grease or other contaminants.  

Note

: Dahua recommends attaching a “drip loop” (flex or hard conduit) during installation to ensure 

condensation does not form in the mount or the conduit. 

4.1  Installing the Camera 

1. 

Remove the camera, the mounting template, multi-purpose tool, and the hardware package from 

the box. 

2. 

Remove the bottom cover from the camera to access the analog output port and the camera 

menu control buttons. 

3. 

Connect an analog TV monitor to the CVBS Output port. This optional step assists with 

positioning and configuring the camera to produce the desired video scene.  

4. 

Apply the mounting template to the mounting medium. Pre-drill the four perimeter holes for the 

expansion bolts, using a drill bit that is no wider than the expansion bolt.  

5. 

Drill the center hole to route the cable from the camera through the installation medium. 

6. 

Insert an expansion bolt into each pre-drilled perimeter hole.  

7. 

Route the cables from the back of the camera through the installation medium and align the four 

holes on the base of the camera with the expansion bolts. 

8. 

Insert a bolt into the expansion bolts and tighten with the Multi-purpose tool. Repeat this 

procedure with the other three (3) expansion bolts. 

9. 

Adjust the sunshield, if necessary. Loosen the screw on the top of the camera and slide the 

sunshield back and forth to the desired location, then tighten the screw. 

10.  Connect the external cables from the camera to the appropriate cables for video, power, alarm 

I/O, and audio. 

11.  Press the Reset button for five (5) seconds to reset camera and to send video along the analog 

connection, if connected. 

Содержание A83ALBZ

Страница 1: ...Multi sensor HDCVI Panoramic IR Bullet Camera DH HAC PFW3601N A180 Quick Start Guide Version 001 001 Dahua Technology USA Inc...

Страница 2: ...mpliance 4 1 3 Legal Notices 4 Copyright 4 Trademarks 4 1 4 Disclaimer 5 2 Unpacking 6 3 Installation and Configuration 7 3 1 External Cable 7 Cable Connections 7 Alarm I O Port Configuration 7 3 2 Fr...

Страница 3: ...source however the unit is operational only when the ON OFF switch is in the ON position The power cord is the main power disconnect device for switching off the voltage for all units Operate the uni...

Страница 4: ...ct the longevity of the CCD or the CMOS sensor Transport use and store the unit within the specified temperature and humidity range Do not place the unit in a wet dusty extremely hot or an extremely c...

Страница 5: ...h or wipe a dome cover during installation this cover is an optical device Refer to the following methods clean the dome cover Stained with dirt Use an oil free soft brush or blower to gently remove t...

Страница 6: ...ee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off...

Страница 7: ...y information Dahua accepts no liability for damage resulting directly or indirectly from faults incompleteness or discrepancies between this guide and the product described Dahua is not liable for an...

Страница 8: ...tative The original packing carton is the safest container to transport the unit in the event the unit must be returned for service Retain the carton and all shipping material for future use Please re...

Страница 9: ...ut Refer to Table 3 2 for more details 5 POWER Power input port Power port Input 12 VDC power Use power according to the device tag Table 3 1 Alarm I O Port Configuration Port Name Color Name Note I O...

Страница 10: ...put signal is grounded then no alarm input signal is detected Figure 3 2 Alarm Output The ALARM_OUT and the ALM_OUT_GND ports form a switch which is used to provide alarm output Normally the switch is...

Страница 11: ...nsation does not form in the mount or the conduit 4 1 Installing the Camera 1 Remove the camera the mounting template multi purpose tool and the hardware package from the box 2 Remove the bottom cover...

Страница 12: ...lti purpose Tool to loosen the three set screws along the shaft of the camera then position the camera by tilting twisting and rotating the camera as shown in the figure below Note Do not rotate the c...

Страница 13: ...DVR 2 From the DVR select the Main Menu and choose Setting Then select the System tab and select the PTZ link on the left side menu 3 Select the appropriate channel number for the camera 4 Set CONTROL...

Страница 14: ...AUDIO SOURCE as HDCVI Figure 5 2 9 Click Save to store the changes 10 Click the right mouse button and select PTZ Control The HDCVI DVR opens the PTZ Setup menu Figure 5 3 11 Click the Camera icon to...

Страница 15: ...e to access the camera s menu Button Function Access the camera s settings menu Select a menu item Select a setting value Adjust lens zoom and auto trigger function Adjust lens focus Trigger autofocus...

Страница 16: ...il from the dome cover Then use an oil free cotton cloth or paper soaked with alcohol or detergent to clean the lens from the center of the dome to outside Change the cloth several times to ensure the...

Страница 17: ...logy USA Inc 23 Hubble Irvine CA 92618 Tel 949 679 7777 Fax 949 679 5760 Email sales usa global dahuatech com Rev 001 001 2017 Dahua All rights reserved Design and specifications are subject to change...

Отзывы: