Main Function Description
45
5.8
UserSetControl
In this property, you can save or load the parameter scheme set by user and set the default parameter
configuration when opening the client, as shown in Figure 5-8; please refer to Sheet 5-9 for detailed
parameter settings.
Figure 5-8 User Set Control
Sheet 5-9 User Set Control - Parameter Explanation
Parameter
Explanation
UserSetSelector
UserSetSelector: supports Default, UserSet1 and UserSet2.
Selects which series to use for the subsequent UserSetLoad and UserSetSave
operation.
UserSetLoad: restores the camera configuration to the configuration that user
selected.
UserSetSave: saves the current configuration to the selected series, but the
Default series does not support saving.
UserSetLoad
UserSetSave
UserSetDefault
Default user set when the power is on. UserSet1 and UserSet2 need to
execute UserSetSave before display.
UserSetLoadLastUserSet
The last user configuration the user used.
UserSetLoadStatus
User set load status.
Displays whether the configuration has been successfully loaded.
5.9
CounterAndTimerControl
In this property, the counter can divide the frequency of the external input trigger signal and execute
exposure control according to the user’s logic, as shown in Figure 5-9; please refer to Sheet 5-10 for
detailed parameter settings.
Please set TriggerSource in 5.3 AcquisitionControl before using.