background image

 

Product  Installation

    25 

 

such devices in parallel because such devices have strong electro-magnetic radiation which is easy 

to couple to the camera's transmission line. 

 

Shelter  grounds  of  all  devices  must  be  connected  together  and  take  single  point  grounding. 

Multi-point  grounding  easily  leads  to  voltage  difference  between  devices  which  form  circuits  to 

induce couple electro-magnetic interference. 

 

Power supply for camera and that for PC must be from the same AC power distributor in order to 

connect  their  shelter  grounds  and  avoid  multi-point  grounding.  High-power  mechanical  and 

electrical equipment do not directly use this AC power. 

 

Magnetic  ring  can  be  added  to  the  power  control  cord  of  camera  in  order  to  absorb 

electro-magnetic interference signals. 

 

Please  keep  the  suitable  humidity  and  operate  with  wrist  strap,  anti-static  clothes  and  shoes  to 

reduce ESD. 

3.1.2.2

 

Heat Dissipation 

Under the condition of a stable condition (temperature and humidity, air flow, installation location, etc.) 

the camera will reach a temperature balance in 1 or 1.5 hours, which means that the cover temperature 

will  not  rise  any  longer.  It  is  important  to  ensure  the  cover  temperature  beyond  50

  and  there  is  a 

temperature  difference  of  25

  between  inner  main  heat  source  and  outside  cover  in  this  balanced 

condition. When the cover temperature is under 50

, the electronic chip inside will not suffer damage. 

Recommend several good methods of controlling the temperature

 

 

Ambient temperature should be beyond 30

, it is best to work in an air-conditioned environment. 

 

Installed  on  the  object  with  good  thermal  conductivity,  such  as  large  metal  which  is  easy  to 

dissipate heat. 

 

Ensure certain air flow to dissipate heat. 

3.2

 

Software Installation 

Application installation steps of host computer are as follows:   

Step1

 

Turn the PC on. 

Step2

 

Double client the installation package and install MV Viewer program according to the prompt 

on the interface. You can see Figure 3-1 after installation.   

 

Please get in touch with relevant technical supporter to obtain the installation package. 

Содержание 3000 Series

Страница 1: ...USB3 0 Area Scan Industrial Camera User Manual V1 0 0 Dahua Technology Co Ltd ...

Страница 2: ...llows Symbol Description Indicates a potentially hazardous situation which if not avoided could result in death or serious injury Indicates a moderate or low level of potential danger which if not avoided could result in minor or moderate injury Indicates a potential risk that if ignored could result in damage to device loss of data degraded performance or unpredictable results It can help you sol...

Страница 3: ...ich is to avoid liquid flowing into the device Please install the device in a location with good ventilation do not block the ventilation opening of the device Use the device only within the rated input and output range Please do not dismantle the device at will Please transport use and store the device within the allowable range of humidity and temperature Please connect the product with I struct...

Страница 4: ...ication 20 2 3 1 Power and USB Port Electrical Specifications 20 2 3 2 IO Port Electrical Specification 20 2 4 Indicator Light Description 23 3 Product Installation 24 3 1 Hardware Installation 24 3 1 1 Default Accessories 24 3 1 2 Camera Installation 24 3 2 Software Installation 25 4 Network Settings 27 5 Main Function Description 33 5 1 DeviceControl 34 5 2 ImageFormatControl 36 5 3 AcquisitionC...

Страница 5: ... theory with power supply Mechanical Dimension 29mm 29mm 29mm mm 128MB on board frame buffer for image data transmission Supports software trigger external trigger mixed mode free run mode Supports sharpness noise reduction gamma correction LUT black level correction brightness contrast and other ISP functions Supports interpolation algorithm white balance algorithm color conversion matrix hue sat...

Страница 6: ...NR 38dB Gain 0dB 18dB Exposure Time 16μS 1S Image Format Mono Mono8 10p Color BayerRG8 10p BayerGB8 10p Physical Interface Data Interface USB3 0 IO Interface 6 pin Hirose connector 1 channel opto isolated input 1 channel opto isolated output 2 channel without opto isolation and configurable for input output Lens Mount C Power Weight Dimension Certification Power Supply Power supply via USB connect...

Страница 7: ...e Ratio SNR 38dB Gain 0dB 18dB Exposure Time 16μS 1S Image Format Mono Mono8 10p Color BayerRG8 10p BayerGB8 10p Physical Interface Data Interface USB3 0 IO Interface 6 pin Hirose connector 1 channel opto isolated input 1 channel opto isolated output 2 channel without opto isolation and configurable for input output Lens Mount C Power Weight Dimension Certification Power Supply Power supply via US...

Страница 8: ...e connector 1 channel opto isolated input 1 channel opto isolated output 2 channel without opto isolation and configurable for input output Lens Mount C Power Weight Dimension Certification Power Supply Power supply via USB connector Power Consumption 3 4W Temperature Storage Temperature 30 80 Operating Temperature 30 50 Dimension 29mm 29mm 29mm Not including the lens mount and the rear case conne...

Страница 9: ...d output 2 channel without opto isolation and configurable for input output Lens Mount C Power Weight Dimension Certification Power Supply Power supply via USB connector Power Consumption 3 8W Temperature Storage Temperature 30 80 Operating Temperature 30 50 Dimension 29mm 29mm 29mm Not including the lens mount and the rear case connectors Weight 60g Certification Conforms to CE FCC UL RoHS USB3Vi...

Страница 10: ... input output Lens Mount C Power Weight Dimension Certification Power Supply Power supply via USB connector Power Consumption 4 2W Temperature Storage Temperature 30 80 Operating Temperature 30 50 Dimension 29mm 29mm 29mm Not including the lens mount and the rear case connectors Weight 60g Certification Conforms to CE FCC UL RoHS USB3Vision and GenICam Software MV Viewer or GenICam and USB3Vision ...

Страница 11: ...Certification Power Supply Power supply via USB connector Power Consumption 4 2W Temperature Storage Temperature 30 80 Operating Temperature 30 50 Dimension 29mm 29mm 29mm Not including the lens mount and the rear case connectors Weight 60g Certification Conforms to CE FCC UL RoHS USB3Vision and GenICam Software MV Viewer or GenICam and USB3Vision supported devices A7500M CU75 7000 series 5 0MP US...

Страница 12: ...to isolation and configurable for input output Lens Mount C Power Weight Dimension Certification Power Supply Power supply via USB connector Power Consumption 4 2W Temperature Storage Temperature 30 80 Operating Temperature 30 50 Dimension 29mm 29mm 29mm Not including the lens mount and the rear case connectors Weight 60g Certification Conforms to CE FCC UL RoHS USB3Vision and GenICam Software MV ...

Страница 13: ...Product Overview 13 Figure 1 2 PYTHON 300 PYTHON 500 PYTHON 1300 Mono Color Spectral Response Figure 1 3 PYTHON 1300 Mono NIR Spectral Response ...

Страница 14: ...Product Overview 14 Figure 1 4 PYTHON 2000 PYTHON 5000 Mono Color Spectral Response Figure 1 5 PYTHON 2000 PYTHON 5000 Mono NIR Spectral Response ...

Страница 15: ...Product Overview 15 Figure 1 6 CMV4000 Color Spectral Response Figure 1 7 CMV4000 Mono Spectral Response ...

Страница 16: ...1 9 IMX250 Color Spectral Response 1 6 Environmental Requirements The following are the environmental requirements for USB3 area scan industrial camera Temperature and humidity Ambient temperature should not exceed 50 it is best to work in an air conditioned environment ...

Страница 17: ...ture 0 60 Operating ambient humidity 20 80 no condensation Storage temperature 30 80 Storage humidity 20 80 no condensation Please install the device in a stable location indoors with enough heat dissipation space Please keep certain ventilation ...

Страница 18: ...Interface Description 18 2 Interface Description 2 1 Product Dimensions The product dimensions are as follows Figure 2 1 29mm 29mm 29mm Unit mm Figure 2 2 Dimensions of Installation Block ...

Страница 19: ...ssion and power supply To ensure the transmission quality please use certified cables to prevent too much data retransmission and packet loss 2 2 2 I 0 Port Sheet 2 1 Pin Signal Definition Pin Signal Description 1 Line3 GPIO Non isolated software can configure input and output 2 Line1 Opto coupler isolation input 3 Line2 GPIO Non isolated software can configure input and output 1 4 Line0 Opto coup...

Страница 20: ...on 2 3 2 1 Opto isolated Input Sheet 2 3 Opto isolated Input Input Voltage Description DC30V Limit voltage input voltage should not exceed this limit otherwise it will cause damage to the device DC0 24V I O input safe operating voltage range DC0 1 4V Indicates logical 0 DC 1 4V 2 2V Input state reverses and logic state is not certain DC 2 2V Indicates logical 1 Isolated I O input sink current is 5...

Страница 21: ...continuous current of isolated I O output is 50mA Figure 2 5 Opto isolated Output Circuit 2 3 2 3 GPIO Input Sheet 2 5 GPIO Input Voltage Description DC30 0V Limit voltage input voltage should not exceed this limit otherwise it will cause damage to the device DC0 5 0V Input safe operating voltage range the min voltage is DC 3 3V when pulled up from external DC0 0 8V Indicates logical 0 DC 0 8V 2 0...

Страница 22: ...ut swing range 30V is limit voltage which should not be exceeded otherwise it will cause damage to the device DC 3 3V 24V Any voltage within this range can be used to indicates logical 1 it is defined by user DC 3 3V I O output may go wrong if logical 1 has been set within this range it is advised to use 0V to indicates logical 0 The max sink current of isolated I O output is 50mA ...

Страница 23: ...evice booting Blue Blue light high brightness The application software API is connected to the device free mode no image transmission Blue light quick flashing The application software API is connected to the device free mode with image transmission Blue light slow flashing Use trigger mode Red Blue Red and blue light alternate flashing Firmware upgrading Abnormal Red Red light normally on Device ...

Страница 24: ...ime the combined camera heat dissipation should also be concerned 3 1 2 1 Consideration of Static Electromagnetic Interference Lightning and Surge Although the camera has a lightning and anti surge protection design as well as EMI Electro Magnetic Interference and ESD Electro Static Discharge protection design but for security the installation environment and methods should be concerned to avoid o...

Страница 25: ...ondition temperature and humidity air flow installation location etc the camera will reach a temperature balance in 1 or 1 5 hours which means that the cover temperature will not rise any longer It is important to ensure the cover temperature beyond 50 and there is a temperature difference of 25 between inner main heat source and outside cover in this balanced condition When the cover temperature ...

Страница 26: ...Product Installation 26 Figure 3 1 Installation Completion ...

Страница 27: ...ll connected with cables the application installed can detect the online camera The detailed steps for network settings are as follows Step1 Client installation Double client the installation package and install MV Viewer program according to the prompt on the interface You can see Figure 4 1 after installation Figure 4 1 Installation Completion Step2 Open software Double click desktop shortcut op...

Страница 28: ...in Figure 4 2 Figure 4 2 Software Interface Step1 Device connection Click to connect the device Click after successful connection the device interface and property interface are shown in Figure 4 3 and Figure 4 4 respectively You can click to disconnect the device ...

Страница 29: ...Network Settings 29 Figure 4 3 Successful Device Connection Device Interface Figure 4 4 Successful Device Connection Property Interface ...

Страница 30: ...y some device 4 The setup info of the current image which includes video stream image stream display stream image location gray level and RGB color value etc 5 It is to play the adjustment toolbar of the image Play Button You can click according to your needs and select play mode of continuous single frame and multi frame in the drop down list Only when the image is paused can you switch the play ...

Страница 31: ... many files You can click button of File Type on the right and select a specific file format in the drop down menu such as mvcfg The dialogue box will only display the file of this format which is to narrow search range It can implement corresponding operations only when the image is paused or stopped Open recent files File Open the Recent Files submenu includes 10 files which have been recently u...

Страница 32: ...ons only when the image is paused or stopped Display frame rate It is to display the frame rate of current image Display block data It is to display the total frame quantity acquired in the current trigger mode Restore default parameter It is to restore the default config of the menu bar Save GenICamXML Save GenICam protocol in XML language Language Select language Chinese or English Help User man...

Страница 33: ...mera supports three user levels which are Beginner Expert and Guru The parameter items in corresponding property interface of each level are slightly different Please refer to No 9 in Sheet 4 1 for user level selection The parameter items displayed in black indicate that the parameter can be changed or set The parameter items displayed in gray indicate that the parameter does not support change or...

Страница 34: ...Red Green or Blue in BalanceRatioSelector and set BalanceRatio to 1 Format Gamma LUT Sharpness Denoising Mono Y Y Y Y Bayer Y Y Y Y Disable Function Set Gamma to 1 Set LUTEnable to False Set SharpnessEnabled to Off Set Denoising to Disable Format Contrast DigitalShift Brightness Mono Y Y Y Bayer Y Y Disable Function Set Contrast to 50 Set DigitalShift to 0 Set Brightness to 50 5 1 DeviceControl Yo...

Страница 35: ...eVersion Device version including updated date and SVN number in the bracket DeviceFirmwareVersion Device firmware version including updated date and SVN number in the bracket and the number following the semicolon represents the hardware version DeviceSerialNumber Device serial number DeviceUserID User programmable device identifier DeviceTLType The protocol type used by the camera transport laye...

Страница 36: ...or board mainboard DeviceTemperature The actual temperature of sensor board mainboard DeviceUSBMode The current connected USB mode such as USB3 0 5 2 ImageFormatControl In this property you can change image size image pixel format region of interest ROI and test image mode etc as shown in Figure 5 2 please refer to Sheet 5 3 for more details about parameter settings Please refer to 1 4 Main Techni...

Страница 37: ...ased on the original size of the sensor but not the image after ROI If the output format of the color type is Bayer the image format needs to be modified after reversing vertically to interchange BayerRGxxx and BayerGBxxx PixelFormat Image output format Different models support different formats PixelSize Total size in bits of a pixel of the image PixelColorFilter Type of color filter that is appl...

Страница 38: ...tion Parameter Explanation AcquisitionMode Image acquisition mode SingleFrame acquires one frame at a time and stops to capture frames automatically when finished MultiFrame acquires frames specified by AcquisitionFrameCount and stops to capture frames automatically when finished Continue acquires frames continuously until an Acquisition Stop signal is given to stop to capture frames AcquisitionSt...

Страница 39: ... and select On Off in TriggerMode to enable disable the trigger mode You need to trigger AcquisitionStart at first when triggering together then you can trigger FrameStart to acquire frames TriggerMode TriggerSoftware Trigger mode TriggerSource supports SoftwareTrigger and lineN HardwareTrigger When you select SoftwareTrigger click or call API in TriggerSoftware to generate software trigger When y...

Страница 40: ...rightness The modified value is displayed in gray in ExposureTime Continue means the camera can continuously modify the exposure time according to the ambient brightness The modified value is displayed in gray in ExposureTime ResultingframeRateAbs The max frame rate the camera can achieve The max frame rate the camera can achieve depends on the network transmission bandwidth pixel size resolution ...

Страница 41: ...elected to be the output you can select the trigger source Current supported trigger sources are as follows ExposureActive outputs the signal when exposure starts FrameTriggerWait outputs the waiting signal for frame trigger Timer0Active outputs the signal when the Timer0 counts up UserOutput0 outputs the value user set in Userset0 AcquisitionTriggerWait outputs the waiting signal for acquisition ...

Страница 42: ...arger the gain the brighter the image The set range is different for different types and the default value is 1 The analog gain is preferentially enabled BlackLevelSelector BlackLevelSelector is used to select the black balance channel BlackLevel is used to eliminate the impact of Sensor s dark current The dark current is a phenomenon that the image brightness is a value greater than 0 when it is ...

Страница 43: ...he current scene An algorithm for searching gray region is used to find possible gray region in Bayer data When BalanceRatioSelector is set as Continues it represents continuous white balance mode White balance correction is only available for the color camera White balance of the mono camera defaults to 1 BalanceRatio BalanceWhiteAuto Gamma Gamma value setting It is a non linear correction for im...

Страница 44: ... values in LUTValue LUTIndex LUTValue LUTValueAll Sets all the values of Index to the same value 5 7 TransportLayerControl In this property you can set parameters related to camera s transport layer protocol as shown in Figure 5 7 please refer to Sheet 5 8 for detailed parameter settings Figure 5 7 Transport Layer Control Sheet 5 8 Transport Layer Control Parameter Explanation Parameter Explanatio...

Страница 45: ...onfiguration that user selected UserSetSave saves the current configuration to the selected series but the Default series does not support saving UserSetLoad UserSetSave UserSetDefault Default user set when the power is on UserSet1 and UserSet2 need to execute UserSetSave before display UserSetLoadLastUserSet The last user configuration the user used UserSetLoadStatus User set load status Displays...

Страница 46: ... the source to increment the Counter FrameTrigger FrameStart CounterReset The selected counter used for software reset TimerSelector Selects the counter needs to configure The default is Timer0 TimerTriggerSource Selects the trigger source of the start timer The default is ExposureStart TimerTriggerActivation Selects the trigger mode of the start timer RisingEdge FallingEdge or AnyEdge TimerDelay ...

Страница 47: ...e is selected no denoising process is performed When Bilateral is selected it uses Bilateral algorithm to denoise Denoising When Bilateral is selected the level of denoising can be set DigitalShift Adjusts DigitalShift The brightness can be doubled when the value increases by one Brightness Brightness Adjust the brightness value of the exposure target The default value is 50 The greater the value ...

Страница 48: ...over the camera but connection failed Reason analysis The camera fails to boot up normally Another client has been connected to the camera Solutions Reboot the camera use USB port on the back of the PC in order to supply enough power or disconnect the other client that has been connected and then connect this client 3 The preview interface is all black in the application Reason analysis Lens apert...

Страница 49: ...e and make sure external connection is correct 5 The image is reverse when the client software checks image Reason analysis The installation direction is wrong during device installation Solutions You can correct the image via Condition Image Format Control Reverse X horizontal flip or Reverse Y vertical flip in the client software ...

Страница 50: ...f image sensor The color camera is equipped with a low pass filter that cuts off to the near infrared band If you have special requirements such as not using a color filter or using another light transmitting filter you can replace the entire filter mount of the image sensor no need of removing the cover If the surface of the filter needs to clean We recommend using the special cleaning agent for ...

Страница 51: ... 社会的安全我们的责任 SOCIALSECURITYISOURRESPONSIBILITY Dahua Technology Co Ltd Address No 1187 BinAn Road Binjiang District Hangzhou P R C Postcode 310053 Service Hotline 400 672 8166 Website www dahuatech com ...

Отзывы: