User’s Manual
52
4.3.1
Introducing Alarm Port
The alarm input ports are dependent on the model you purchased.
Alarm ports
Table 4-1
Alarm port description
Icon
Description
1,2,3,4,5,6,7,8,9,10,11,
12,13,14,15,16
ALARM 1 to ALARM 16. The alarm becomes active in low voltage.
NO1 C1, NO2 C2, NO3
C3, NO4 C4
There are four groups of normal open activation output (on/off button).
NO5 C5 NC5
There is one group of normal open activation output (on/off button).
CTRL 12V
Control power output of the 6th alarm output channel. Voltage current: 500
mA.
When there is an alarm output, close the power output.
When the alarm is cancelled, open the power output.
+12V
Rated current.
Voltage current: 500 mA.
Ground cable.
485 A/B
485 communication port. They are used to control devices such as decoder.
120 Ω should be parallel connected between A, B lines if there are too many
PTZ decoders.
T+, T-, R+, R-
Four-wire full-duplex RS-485 port.
T+ T-: output wire.
R+ R-: input wire.
4.3.2
Alarm Input
Refer to the following figure for more information.
Grounding alarm inputs which includes NO (Normally Open) and NC (Normally Closed) type.
Parallel connect COM end and GND end of the alarm detector (Provide external power to the
alarm detector).
Parallel connect the Ground of the DVR and the ground of the alarm detector.
Connect the NC port of the alarm sensor to the DVR alarm input (ALARM).
Use the same ground with that of DVR if you use external power to the alarm device.
Содержание XVR Series
Страница 1: ...Digital Video Recorder User s Manual V1 5 0 ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD...
Страница 20: ...User s Manual 8 Fix HDD Connect cables Install the bracket and then fasten the screws...
Страница 115: ...User s Manual 103 Main menu...
Страница 201: ...User s Manual 189 Search result diagram Search result list...
Страница 221: ...User s Manual 209 Search results diagram Search results list Double click the video or click...
Страница 240: ...User s Manual 228 List For the data displayed in graph see Figure 5 187 Graph...
Страница 283: ...User s Manual 271 Main stream Sub stream...
Страница 327: ...User s Manual 315 Login Click Forgot Password Reset password Click OK...
Страница 339: ...User s Manual 327 Abbreviations Full term VBR Variable Bit Rate VGA Video Graphics Array WAN Wide Area Network...
Страница 357: ...User s Manual 345 Neutral cable...
Страница 362: ...User s Manual 350 Enable IP MAC address filtering function to limit the range of hosts allowed to access the device...
Страница 363: ...User s Manual...