Pilot's Operating Handbook
Section 4
Normal procedures
EASA Approved
Edition 1 - January 15, 2018
Rev. 2
Page 4.4.33
After engine start with GPU
1 -
SOURCE selector
BATT
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 -
Electrical network
Check
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3 -
GPU
Disconnect
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performed by ground personnel
4 -
GPU DOOR
Check OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 -
GENERATOR selector
MAIN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6 -
MAIN GEN
Check OFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
●
NOTE
●
MAIN GEN
normally goes off as soon as
STARTER
goes off.
●
If
MAIN GEN
does not go off :
7 -
Ng
Increase over 70 %
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
To start main generator
8 -
Generator and battery AMPS
Check charge
. . . . . . . . . . . . . . . . . . . . . . . . . . .
On EIS of MFD
9 -
Battery and ESS. bus VOLTS
Check voltage
≈
28 Volts
. . . . . . . . . . . . . . . .
On EIS of MFD
10 -
CAS display
Check
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11 -
A/C switch
As required
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
12 -
BLEED switch
AUTO or MAX DIFF
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
When ground personnel is cleared from propeller area :
13 -
Perform procedure
After engine start
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Refer to procedure hereafter
End of procedure.